10.5 Electrical connections
EVEN THE TINIEST PROCEDURE
OF AN ELECTRICAL NATURE
MUST BE CARRIED OUT BY PRO-
FESSIONALLY QUALIFIED STAFF.
BEFORE CONNECTING THE MA-
CHINE MAKE SURE THAT:
• THE MAIN POWER RATING COR
-
RESPONDS TO THE MACHINE
RATING AS SHOWN ON THE
MACHINE PLATE;
• ALL MAIN POWER COMPO
-
NENTS ARE IN GOOD CONDI-
TION;
• THE ELECTRICAL SYSTEM
IS PROPERLY GROUNDED
(GROUND WIRE MUST BE THE
SAME CROSS-SECTION AREA
AS THE LARGEST POWER SUP-
PLY CABLES OR GREATER);
• MAKE SURE THAT THE ELEC
-
TRICAL SYSTEM FEATURES A
CUTOUT WITH DIFFERENTIAL
PROTECTION SET AT 30 MA.
As envisaged by the regulations in force, the machine is
not equipped with a master circuit breaker, but simply
has a plug-socket connection to the electrical mains.
The machine is supplied with free cable of mt.
3
. A plug
corresponding to the following requirements must be
connected to the cable:
• Conformity to Norm
IEC 309
•
230/400 Volt – 16A
•
3P + Ground
•
IP 44
Only for versions with inverter
• Conformity to Norm
IEC 309
• 220/240 Volt – 32A
• 2P + Ground
• IP 44
Space s.r.l.
7300-M009-0_P
GA2645 - GA2645D - GA2645V
Valid for version with pressure regulator -
GA2645ID.26
Fig. 9B
IN CASE OF A CHANCE SUP-
PLY FAILURE, AND/OR BEFORE
ANY PNEUMATIC CONNECTIONS,
MOVE THE CONTROLS TO THE
NEUTRAL POSITION.