Page 1
2
of
20
Fig. 7
IMPORTANT: CORRECT ALIGNMENT OF THE BURNER ASSEMBLY IS CRUCIAL TO THE SAFE
OPERATION OF THE APPLIANCE.
4.1.2
Position the Burner Assembly spigot in the Venturi inlet to align the M5 tapped holes in the spigot with the clearance
holes in the Venturi and secure with the Qty 4 - M5x6 set screws provided.
4.2
Ultra 7, 14, 21, 28, 42
4.2.1
The appliance should be raised and suspended from chains or drop rods or from brackets fixed to vertical surfaces
which have been previously installed in accordance with section 3.1 - Suspension.
4.2.2
Connect the gas supply in accordance with Section 3.2. - Gas Supply, of these Installation Instructions.
4.2.3
Using twin core and earth flexible supply cable, as specified in Section 3.3.2, suitable for 230V ~ 50Hz 25W supply,
connect the 4 pin electrical socket provided (fitted to junction box, attached to the Control Valve) as follows:-
Brown
-
to terminal marked 1
Blue
-
to terminal marked 2
Green/Yellow
-
to terminal marked
7
External fuse required - 3 amp.
See section 3.3 for electrical supply requirements.
4.3
Ultra 7/3.5, 14/7, 21/10.5, 28/14, 42/21
(HI/LO)
4.3.1
The appliance should be raised and suspended from chains or drop rods, or from brackets fixed to vertical surfaces
which have been previously installed in accordance with Section 3.1. - Suspension.
4.3.2
Connect the gas supply in accordance with Section 3.2. - Gas supply, of these Installation Instructions.
4.3.3
Using three core and earth flexible supply cable as specified in section 3.3.3, suitable for 230v ~ 50Hz 25W supply,
connect the 4 pin electrical socket provided (fitted to junction box, attached to the Control valve) as follows:-
Brown
-
to terminal marked 1
Blue
-
to terminal marked 2
Black
-
to terminal marked 3
Green/Yellow
-
to terminal marked
7
External fuse required - 3 amp
See Section 3.3 for electrical supply requirements.