7. 

GAS CONNECTIONS 

 
1.  Gas piping for the house must be sized to be capable of satisfying the entire demands of the 

house should all equipment be operating at the same time.  Please use Table 1 as a guide 
for the sizing of piping for the house.  An example using this table is shown. 

 
2.  Connect  to  the  supply  tank  or  manifold  in  accordance  with  the  National  Gas  Safety 

Regulations.    Authorities  having  jurisdiction  should  be  consulted  before  the  installation  is 
made.  

 
3.  Pipe joint compounds must be resistant to the action of 

liquefied petroleum (LP) gases. 

 
4.  Gas connections to individual brooders can be made in 

several ways to fit individual operation practices.  
Brooders can be “hard-piped,” or they can utilize 
flexible gas connectors, or they can utilize rubber 
hosing suitable for LP gas usage (to allow movement of 
the brooders for cleaning, etc.).  Check with the 
authorities having jurisdiction and/or National Gas 
Safety Regulations prior to choosing an individual gas 
connection method.   

 

 

 

 

 

 

 

 

 

                                            

 

 

 

 FIGURE 5b 

5.  A  field  installed  keyless  manual  shut-off  valve  must  be  installed  in  the  gas  piping  to  each 

brooder.  This will allow service of individual brooders without having to shut down the entire 
gas supply system.  When installing the gas line, it is recommended to connect a sediment 
trap (see illustration, previous page) in the gas line at a point before the gas line enters the 
house.  This trap or “drip leg” acts to trap impurities and water that can condense out of the 
gas.  It helps to keep impurities from entering the appliance and causing potential damage 
to gas valves, etc.  Periodically remove the cap from the drip leg and drain any accumulation 
of dirt and/or water. 

 
6.  After  all  gas  connections  and  adjustments  are  made,  check  all  gas  connections  for  leaks 

(not  just  the  gas  connections  at  the  brooders)  using  a  heavy  soap  suds  solution.  

WARNING:  DO NOT USE AN OPEN FLAME OF ANY KIND TO TEST FOR LEAKS! 

 
7.  It  is  recommended  that  a  pressure  gauge  be  installed  at  the  end  of  the  gas  piping  run  to 

allow  you  to  check  the  gas  supply  pressure  in  the  system.    This  needs  to  be  capable  of 
accurately measuring in units of inches of water column or mbar. 

 
 

 
 
 
 
 

Содержание SRB40CRE-B2

Страница 1: ...filters on a regular basis to allow proper brooder operation FOR YOUR SAFETY EXHAUST FANS MUST be operating on an appropriate cycle when brooders are operating to avoid a high concentration of carbon...

Страница 2: ...ervice accessibility For optimum temperature control for brooders requiring remote temperature controls do not locate thermostats in shaded or draughty locations outside the area to be heated The sens...

Страница 3: ...kg Gas Connection Rc with Galvanized Canopy 3 BROODER CONTROL OPTIONS Control No 2 For single or multi zone installations using central or multiple thermostats This 24 volt AC zone type control also c...

Страница 4: ...illips Crescent Wrench 2 each 2 Place the Low Profile Hanging Bracket onto the Canopy as shown Secure the bracket to the center of the Canopy with a 20 screw nut and washer from the Fastener Kit Assem...

Страница 5: ...NOTE DO NOT COMPLETELY TIGHTEN FASTENERS AT THIS STAGE YET 7 Attach the Control Arm Assembly to the Manifold Support Bracket Assembly as shown in Figure 3 using the V clamp and the two 2 10 24 screws...

Страница 6: ...the Fastener Kit Note Combustion air ring for Natural gas not shown 12 Flip the brooder over to its original position and place the Pilot Shield perforated onto the Pilot Assembly 13 Attach the Safety...

Страница 7: ...APPLY AT ORIFICE FITTING PILOT ASSEMBLY AND FIELD CONNECTION AT THE GAS VALVE 5 MINIMUM CLEARANCES TO COMBUSTIBLES Minimum clearances to combustible materials shall be measured from the outer surface...

Страница 8: ...hor it to the house structure above each brooder to prevent it from falling onto the litter if the cable chain breaks or the winch fails THE GAS HOSE SHOULD NEVER BE USED AS A SAFETY CHAIN 3 Connect t...

Страница 9: ...idual gas connection method FIGURE 5b 5 A field installed keyless manual shut off valve must be installed in the gas piping to each brooder This will allow service of individual brooders without havin...

Страница 10: ...into contact with the canopy Item Number Part Number Description Qty 1 2112 VALVE MANUAL BALL 3 8 BSP MALE 1 2 4262347 MALE FTG 45FLARE 3 8TUBEx3 8NPT 1 2a 4262334 MALE FTG 45FLARE 3 8TUBEx1 2NPT 1 3...

Страница 11: ...cates a leak in the system If the pressure drop occurs check the joints connectors and other possible points of leakage with an approved high quality leak detection solution NEVER USE A MATCH OR OPEN...

Страница 12: ...replacing the plug Repeat the gas leak test at the plug FIGURE 6a Control No 9 GAS PRESSURE TABLE BROODER MODEL GAS TYPE MANIFOLD PRESSURE SUPPLY PRESSURE Minimum Nominal SRB40CRE N Natural gas G20 6...

Страница 13: ...or at the house Using the above house configuration example calculate the gas pipe sizing First calculate the total distance from the second stage regulator to the furthest brooder In Figure 9 above t...

Страница 14: ...lator m Flow Capacity Required kW Distance Used from Table m ft Smallest Pipe Size and Capacity From Table kW Btu hr 7 and 14 62 11 7 61 5 17 6 and 13 53 5 23 4 61 5 35 2 5 and 12 45 35 2 46 41 3 4 an...

Страница 15: ...an the minimum size specified will result in the brooder not functioning properly 6 A Thermostat is also required for each brooder or group of brooders as shown in the schematic The schematic Figure 8...

Страница 16: ...ready position A safety devise prevents the knob from being fully depressed until the thermocouple has cooled down sufficiently to de energize the power unit after which the knob will be effective aga...

Страница 17: ...thermal evacuation Ventilation by thermal evacuation is sufficient if 10m3 h of exhaust air per kW of operating heat input are ventilated out of the installation room The air products of combustion mi...

Страница 18: ...of all the air supply openings shall not be smaller than the total area of the unobstructed cross sections of all the exhaust openings Slits and gaps of fixed cross sections can also be used as air s...

Страница 19: ...ing a smaller diameter than the actual orifice hole size see the brooder nameplate or instruction manual DO NOT USE A DRILL as this will increase the orifice hole and result in overfiring 3 Clean arou...

Страница 20: ...s at the end of the house This will result in a flame that is more stable to observe If at anytime 25 or more of the flame turns yellow or on an annual basis we recommend that the burner and orifices...

Страница 21: ...sh available as an accessory Part No 43295010 or other small wire brush After cleaning the burner ports use the same brush to clean inside the burner base and venturi Compressed air can be blown onto...

Страница 22: ...ve the outer pilot housing from the pilot assembly by pulling the tab with a pair of pliers After cleaning reassemble the pilot assembly in reverse order NOTE Make sure that the outer pilot housing sn...

Страница 23: ...to be lowered gently under its own weight FIGURE 15 3 Unscrew the main burner orifice counter clockwise with a socket or wrench FIGURE 15a 4 Apply a small amount of thread sealant to the threads of t...

Страница 24: ...s G30 79 0 368mm 8 Replace the housing tab and windshield 9 Adjust gas pressure and check for gas leaks by following the procedure 7a Instructions for testing for gas leaks and proper gas pressure as...

Страница 25: ...GAS MODELS ONLY Models operating on Natural Gas must have an additional combustion air ring and a burner pan having an air inlet hole This is required for proper combustion of the gas and air mix Ass...

Страница 26: ...f the performance use the gas pipe sizing table in this manual Service Clean the orifice as necessary Maintenance Service See the instructions for correct orifice size and replace if necessary Service...

Страница 27: ...utane Gas G30 24 4mbar 1 1 1 28 43305980 Main Burner Orifice Fitting Sub Assembly 1 1 1 29 30397000 1 2 x 3 8 Tube Fitting 1 1 30 03600020 3 8 Compression Sleeve 1 1 1 31 03601020 3 8 Compression Nut...

Страница 28: ...Form 43539178 Oct 2019 27 ALL ILLUSTRATIONS ARE INTENDED TO GIVE THE GENERAL IMPRESSION OF UNITS ONLY WE RESERVE THE RIGHT TO ALTER ANY SPECIFICATION WITHOUT NOTICE...

Страница 29: ...actory parts modified in any way misused or damaged or which has been used contrary to the manufacturer s written instructions LIMITATION OF WARRANTY THERE ARE NO WARRANTIES EXPRESS OR IMPLIED WHICH E...

Страница 30: ...t as set forth above FOR YOUR RECORDS Space Ray Brooder Model Number Date Installed Serial Numbers For replacement parts please contact your local distributor or SPACE RAY UK 4 6 Chapel Lane Claydon I...