Form 43539178
Oct 2019
14
No. of Brooders x 12.0VA x 1.25 Safety Factor = Transformer Size
No. Brooders
Minimum Transformer VA
14
210
15
225
16
240
17
255
18
270
19
285
20
300
21
315
22
330
23
345
24
360
25
375
4.
The wire to the #2 type brooders MUST be a minimum 2.5mm
2
.
5. Failure to connect the #2 type brooders to the minimum power supply recommended or to
use a cable less than the minimum size specified will result in the brooder not functioning
properly.
6. A Thermostat is also required for each brooder or group of brooders as shown in the
schematic. The schematic (Figure 8) shows a group of four (4) brooders controlled by one (1)
thermostat. Additional zone groups having more or less brooders can be added. These
should be wired the same as shown in the schematic.
SCHEMATIC Figure 8
The schematic above shows the lay-out for the No 2. Control 24V. For control No 4 use the same
drawing above only replace the voltage with 230V and the wiring by 1,5mm