Space-Ray SRB40CRE-B2 Скачать руководство пользователя страница 1

 

 

 

Form 43539178 

 

 

 Oct 2019 


 

RADIANT GAS BROODER 

 

MODELS

:

  

 SRB40CRE (-2,-4, -9) with PILOT IGNITION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OWNER/INSTALLER:    For  your  safety  this  manual  must  be  carefully  read  before  installing,  operating  or 
servicing this brooder.  This brooder is intended for use with either Natural Gas or Propane Gas and must be 
installed  in  accordance  with  the  relevant  provisions  of  any  National  Gas  Safety  (Installation  and  Use) 
Regulations.    Due  account  should  also  be  taken  of  any  obligations  arising  from  any  National  Health  and 
Safety  at  Work  Regulations,  National  and  Local  Building  Regulations  and  National  Electrical  Wiring 
Regulations.  The appliance must be installed, and where necessary, converted for use on other gases, by a 
qualified installer. 

 

WARNING:  Improper installation, adjustment, alteration, service or maintenance can cause injury, property 

damage  or  death.    Refer  to  this  manual.    For  assistance  or  additional  information,  consult  a  qualified 
installer, service agency or the gas supplier.  

 

INSPECT all combustion air openings into the building and, if necessary, clear as they become blocked by 
litter, dust, feathers or other matter. 

 

INSPECT and clean the brooder filters on a regular basis to allow proper brooder operation. 

 

 

 

FOR YOUR SAFETY: EXHAUST FANS MUST be operating on an appropriate cycle when brooders are operating 
to avoid a high concentration of carbon monoxide.  When used without fresh air, this brooder may give off 
carbon monoxide, an odourless and poisonous gas.  CARBON MONOXIDE POISONING MAY LEAD TO DEATH.  
Early  signs  of  carbon  monoxide  poisoning  resemble  the  flu  with  headaches,  dizziness  and  nausea.    If  you 
experience these signs, GET FRESH AIR IMMEDIATELY!  Have the brooders serviced as soon as possible and 
check the ventilation in the house.   

 

 

 

These brooders are designed for agricultural applications and may operate with the use of either Natural Gas 
or  Liquid  Propane  (LP)  Gas.    Check  the  brooder’s  nameplate  to  determine  the  correct  gas  type  before 
proceeding with installation. 

 

 

 

 

 

IF YOU SMELL GAS: 

 

!

  DO NOT try to light any appliance. 

!

  DO NOT touch any electrical switch; do not use any 

telephone in your building. 

!

  IMMEDIATELY  call  your  gas  supplier  from  a  neighbour's 

telephone.    Follow  the  gas  supplier's  instructions.    If  you 
cannot reach your gas supplier, call the fire department. 

 

 

 

 

DO NOT store or use petroleum or 
other flammable vapours and liquids 
in the vicinity of this or any other 
appliance. 
 

SAVE THIS MANUAL 

FOR FUTURE REFERENCE.

 

 

 

INSTALLATION 

AND OPERATION 

INSTRUCTIONS 

 

FOR YOUR SAFETY 

Содержание SRB40CRE-B2

Страница 1: ...filters on a regular basis to allow proper brooder operation FOR YOUR SAFETY EXHAUST FANS MUST be operating on an appropriate cycle when brooders are operating to avoid a high concentration of carbon...

Страница 2: ...ervice accessibility For optimum temperature control for brooders requiring remote temperature controls do not locate thermostats in shaded or draughty locations outside the area to be heated The sens...

Страница 3: ...kg Gas Connection Rc with Galvanized Canopy 3 BROODER CONTROL OPTIONS Control No 2 For single or multi zone installations using central or multiple thermostats This 24 volt AC zone type control also c...

Страница 4: ...illips Crescent Wrench 2 each 2 Place the Low Profile Hanging Bracket onto the Canopy as shown Secure the bracket to the center of the Canopy with a 20 screw nut and washer from the Fastener Kit Assem...

Страница 5: ...NOTE DO NOT COMPLETELY TIGHTEN FASTENERS AT THIS STAGE YET 7 Attach the Control Arm Assembly to the Manifold Support Bracket Assembly as shown in Figure 3 using the V clamp and the two 2 10 24 screws...

Страница 6: ...the Fastener Kit Note Combustion air ring for Natural gas not shown 12 Flip the brooder over to its original position and place the Pilot Shield perforated onto the Pilot Assembly 13 Attach the Safety...

Страница 7: ...APPLY AT ORIFICE FITTING PILOT ASSEMBLY AND FIELD CONNECTION AT THE GAS VALVE 5 MINIMUM CLEARANCES TO COMBUSTIBLES Minimum clearances to combustible materials shall be measured from the outer surface...

Страница 8: ...hor it to the house structure above each brooder to prevent it from falling onto the litter if the cable chain breaks or the winch fails THE GAS HOSE SHOULD NEVER BE USED AS A SAFETY CHAIN 3 Connect t...

Страница 9: ...idual gas connection method FIGURE 5b 5 A field installed keyless manual shut off valve must be installed in the gas piping to each brooder This will allow service of individual brooders without havin...

Страница 10: ...into contact with the canopy Item Number Part Number Description Qty 1 2112 VALVE MANUAL BALL 3 8 BSP MALE 1 2 4262347 MALE FTG 45FLARE 3 8TUBEx3 8NPT 1 2a 4262334 MALE FTG 45FLARE 3 8TUBEx1 2NPT 1 3...

Страница 11: ...cates a leak in the system If the pressure drop occurs check the joints connectors and other possible points of leakage with an approved high quality leak detection solution NEVER USE A MATCH OR OPEN...

Страница 12: ...replacing the plug Repeat the gas leak test at the plug FIGURE 6a Control No 9 GAS PRESSURE TABLE BROODER MODEL GAS TYPE MANIFOLD PRESSURE SUPPLY PRESSURE Minimum Nominal SRB40CRE N Natural gas G20 6...

Страница 13: ...or at the house Using the above house configuration example calculate the gas pipe sizing First calculate the total distance from the second stage regulator to the furthest brooder In Figure 9 above t...

Страница 14: ...lator m Flow Capacity Required kW Distance Used from Table m ft Smallest Pipe Size and Capacity From Table kW Btu hr 7 and 14 62 11 7 61 5 17 6 and 13 53 5 23 4 61 5 35 2 5 and 12 45 35 2 46 41 3 4 an...

Страница 15: ...an the minimum size specified will result in the brooder not functioning properly 6 A Thermostat is also required for each brooder or group of brooders as shown in the schematic The schematic Figure 8...

Страница 16: ...ready position A safety devise prevents the knob from being fully depressed until the thermocouple has cooled down sufficiently to de energize the power unit after which the knob will be effective aga...

Страница 17: ...thermal evacuation Ventilation by thermal evacuation is sufficient if 10m3 h of exhaust air per kW of operating heat input are ventilated out of the installation room The air products of combustion mi...

Страница 18: ...of all the air supply openings shall not be smaller than the total area of the unobstructed cross sections of all the exhaust openings Slits and gaps of fixed cross sections can also be used as air s...

Страница 19: ...ing a smaller diameter than the actual orifice hole size see the brooder nameplate or instruction manual DO NOT USE A DRILL as this will increase the orifice hole and result in overfiring 3 Clean arou...

Страница 20: ...s at the end of the house This will result in a flame that is more stable to observe If at anytime 25 or more of the flame turns yellow or on an annual basis we recommend that the burner and orifices...

Страница 21: ...sh available as an accessory Part No 43295010 or other small wire brush After cleaning the burner ports use the same brush to clean inside the burner base and venturi Compressed air can be blown onto...

Страница 22: ...ve the outer pilot housing from the pilot assembly by pulling the tab with a pair of pliers After cleaning reassemble the pilot assembly in reverse order NOTE Make sure that the outer pilot housing sn...

Страница 23: ...to be lowered gently under its own weight FIGURE 15 3 Unscrew the main burner orifice counter clockwise with a socket or wrench FIGURE 15a 4 Apply a small amount of thread sealant to the threads of t...

Страница 24: ...s G30 79 0 368mm 8 Replace the housing tab and windshield 9 Adjust gas pressure and check for gas leaks by following the procedure 7a Instructions for testing for gas leaks and proper gas pressure as...

Страница 25: ...GAS MODELS ONLY Models operating on Natural Gas must have an additional combustion air ring and a burner pan having an air inlet hole This is required for proper combustion of the gas and air mix Ass...

Страница 26: ...f the performance use the gas pipe sizing table in this manual Service Clean the orifice as necessary Maintenance Service See the instructions for correct orifice size and replace if necessary Service...

Страница 27: ...utane Gas G30 24 4mbar 1 1 1 28 43305980 Main Burner Orifice Fitting Sub Assembly 1 1 1 29 30397000 1 2 x 3 8 Tube Fitting 1 1 30 03600020 3 8 Compression Sleeve 1 1 1 31 03601020 3 8 Compression Nut...

Страница 28: ...Form 43539178 Oct 2019 27 ALL ILLUSTRATIONS ARE INTENDED TO GIVE THE GENERAL IMPRESSION OF UNITS ONLY WE RESERVE THE RIGHT TO ALTER ANY SPECIFICATION WITHOUT NOTICE...

Страница 29: ...actory parts modified in any way misused or damaged or which has been used contrary to the manufacturer s written instructions LIMITATION OF WARRANTY THERE ARE NO WARRANTIES EXPRESS OR IMPLIED WHICH E...

Страница 30: ...t as set forth above FOR YOUR RECORDS Space Ray Brooder Model Number Date Installed Serial Numbers For replacement parts please contact your local distributor or SPACE RAY UK 4 6 Chapel Lane Claydon I...