Form
483S
Rev
Jan
09
Page 3 of 53
3. TECHNICAL DATA
Table 1
MODEL
CBU09/SRL09-N
CBU09/SRL09-L
Heat Input
9.0 kW Hs 8.1 kW Hi
Appliance Type (
II
2H3+
)
A2,
B
22,
C
52
Appliance Category
II
2H3+
Adjusted for
2H G20 20mbar
3+ G30/G31 29/37mbar
Appliance Type (
II
2H3P
)
A2, B
22,
C
12,
C
32,
C
52
Appliance Category
II
2H3P
Adjusted for
2H G20 20mbar
3P G31 37mbar
Setting Pressure
12.5mbar
None
Injector
Ø2.4mm
Ø1.45mm
Pre-injector
None
None
Electrical Supply
230V~50Hz 125W
Fuse Externally
3A
Dimensions
CBU 09 3.10m x 0.46m
SRL 09 5.493m x 0.34m
Weight
CBU 09 31kg
SRL 09 27kg
Gas Connection
R - ½
Flue Size
Ø100mm
Table 2
MODEL
CBU12/SRL12-N
CBU12/SRL12-L
Heat Input
11.4 kW Hs 10.3 kW Hi
Appliance Type (
II
2H3+
)
A2,
B
22,
C
52
Appliance Category
II
2H3+
Adjusted for
2H G20 20mbar
3+ G30/G31 29/37mbar
Appliance Type (
II
2H3P
)
A2, B
22,
C
12,
C
32,
C
52
Appliance Category
II
2H3P
Adjusted for
2H G20 20mbar
3P G31 37mbar
Setting Pressure
12.5mbar
None
Injector
No. 36
Ø1.65mm
Pre-injector
None
None
Electrical Supply
230V~50Hz 125W
Fuse Externally
3A
Dimensions
CBU 12 3.10m x 0.46m
SRL 12 5.493m x 0.34m
Weight
CBU 12 31kg
SRL 12 27 kg
Gas Connection
R - ½
Flue Size
Ø100mm
Содержание CBU09
Страница 2: ......
Страница 55: ...Form 483S Rev Jan 09 Page 53 of 53 NOTES GB IE ES IT PT...