2222
22
4. LED Operation
In short, the Red LED indicates that turbine power is being diverted to the dumpload and the Green LED indicates that the
turbine is spinning and the battery is being charged. The LED operation is detailed in the tables below.
Red LED
Interpretation
Off
Available turbine power directed to battery.
Blinking
Available turbine power directed to dumpload for battery regulation.
On
Available turbine power directed to dumpload by operator request (via either Diversion
Switch or remote Display).
Green LED Interpretation
Off
No charge is going to the batteries; either the windspeed is too low or power is being di-
verted (see Red LED).
On
The batteries are being charged.
5. Setting Regulation Voltage (without Display)
The battery voltage at which the controller begins regulating the battery voltage (i.e. diverting power to the dumpload) is
called the Regulation-On Voltage. This point may be adjusted by using a potentiometer on the controller’s circuit board.
When the controller measures battery voltage above the Regulation-On Voltage for more than approximately 30-40 sec-
onds, the controller begins diverting power.
The voltage at which the controller resumes charging the batteries is refer to at the Regulation-Off voltage. If the control-
ler senses battery voltage below the Regulation-On Voltage for approximately 30-40 second will stop diverting power
and start charging the battery again.
Before adjusting the regulation setpoint
understand that turning up the regulation voltage will not increase the
turbine’s output voltage or current
. This setpoint adjusts the “regulation– on ” voltage for battery charging. Over-
charging will significantly reduce a battery’s life expectancy.
Refer to the following chart for approximate potentiometer set points. Turning the potentiometer clockwise CW increases
the voltage set points.
Note: Before making adjustments it is a good idea to determine the initial potentiometer position by turning the
potentiometer fully CCW while counting the number of turns. Record the number of turns.
Pot Position
Regulation On Voltage
Fully CCW
12.0V 24.0v 36.0v 48.0v
13.0V 26.0v 39.0v 52.0v
4 Turns CCW
13.0V 26.0v 39.0v 52.0v
14.0V 28.0v 42.0v 56.0v
Factory Preset
13.4V 26.8v 40.2v 53.6v
14.4V 28.8v 43.2v 57.6v
9 Turns CW
14.0V 28.0v 42.0v 56.0v
15.0V 30.0v 45.0v 60.0v
13 Turns CW
14.0V 28.0v 42.0v 56.0v
16.0V 32.0v 48.0v 64.0v
Fully CW (18 turns)
14.0V 28.0v 42.0v 56.0v
17.0V 34.0v 51.0v 68.0v
Regulation Off Voltage
Whisper Controller Display
Whisper Controller
Resistive Loadbank
(Dumpload)
Whisper Controller
Electronic Cover
Whisper Controller Electronics
Diversion Switch and
LED’s (Far Side)
Whisper Controller Regulation
Potentiometer
Normal Operation—Whisper Controller
Содержание Whisper 100
Страница 2: ......
Страница 4: ......
Страница 39: ...SOUTHWEST WINDPOWER Whisper 100 Owners Manual Document 0211 REV C 10 05 05 36 Troubleshooting and Repair ...
Страница 40: ...SOUTHWEST WINDPOWER Whisper 100 Owners Manual Document 0211 REV C 10 05 05 38 ...
Страница 41: ...Whisper 100 Owners Manual Document 0211 REV C SOUTHWEST WINDPOWER 10 05 05 3838 39 ...
Страница 42: ...SOUTHWEST WINDPOWER Whisper 100 Owners Manual Document 0211 REV C 10 05 05 40 ...