INSTALLATION
ELECTRICAL INSTRUCTIONS
Electrical Requirements:
120/208 or 120/240 volts AC, 60 Hz
3 wire (plus ground), single phase
30 amp required
THE WARRANTY IS VOID IF THE SMOKER IS CONNECTED TO ANY VOLTAGE OTHER
THAN SPECIFIED ABOVE AND ON THE SMOKER DATA PLATE. THE CHASSIS MUST BE
GROUNDED TO PREVENT POSSIBLE SHOCK HAZARD.
Remove all packing material before connecting the electrical supply to the smoker.
The smoker is not equipped with a power cord from the factory.
Power supply connections should be made with flexible conduit. Use a No. 12 AWG wire suitable for at
least 90° C.
The power is to be left OFF throughout the installation.
Electrical service is provided to the smoker at the main terminal block located behind the access panel in
the lower rear left corner of the smoker
Verify correct voltage at the main terminal block and replace the access panel.
The restraining device must be installed.
WARNING:
This appliance, when installed, must be electrically
grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.2, as applicable.
WARNING
Some components in this smoker operate on 110/120 volts AC. This current is supplied
from L1 and the neutral connection on the terminal block. This must be verified before
applying power to the smoker.