NOTICE
For an appliance equipped with casters, (1) the installation shall be made with a connector that complies with the
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69
or
Connectors for Moveable Gas Appliances,
CAN/CGA-6.16
, and a quick-disconnect device that complies with the
Standard for Quick-Disconnect Devices for
Use With Gas Fuel, ANSI Z21.41
, or
Quick Disconnect Devices for Use with Gas Fuel, CAN1-6.9
, (2) adequate
means must be provided to limit the movement of the appliance without depending on the connector and the quick-
disconnect device or its associated piping to limit the appliance movement and (3) the restraining means should be
attached to a frame member on the back of the unit.
Step 3: Attach Restraint for Appliances Mounted on Casters
WARNING
To avoid accidental gas disconnection and potential explosion:
If disconnection of this restraint is necessary to move the appliance for cleaning, etc., reconnect it when the
appliance is moved to its originally installed position.
Appliances mounted on a stand with casters or other movable surface must be equipped with a restraining means to
prevent accidental stress on the flexible gas connection.
1. Secure the restraining-device bracket (item “B” in the following illustration) to a wall stud located as close as possible
to the appliance connector inlet and outlet connections. Use four #12 screws (items “C”) and plastic anchors (items
“A”) if necessary.
I
NSTALLATION
H
F
I
G
E
D
A
B
C
Note: Kit can be purchased from Southbend (part number 1176867).