SERVICE INFORMATION
SECTION 6:
MODELS: SC-2 & SC-3
CABINET CONTROL PROBLEMS (cont'd)
Heat Exchanger achieves pressure slower than normal (cont'd)
When the vessel is full, allow to stand for several hours or overnight. Unplug and/or uncap all pipe
fittings and allow solution, together with sealant to drain out. During the procedure, exercise
extreme care to avoid personally coming in contact with the acid. If contact occurs, wash acid off
immediately with clean water. Connect hose to pipe fitting and thoroughly flush out vessel with
clean water. Return Heat Exchanger to Cabinet and reconnect all plumbing and bolts.