PERIODIC MAINTENANCE
SECTION 4:
MODELS: SC-2 & SC-3
Fig. 3: The Cooker is the upper section of the steamer and is either a two or three compartment appliance.
Each compartment functions independently with its own controls and is a separated sealed steam chamber
during the cooking operation.
Item A: A Door Gasket is provided on each compartment door and ensures proper sealing of the cooking
compartment.
WASH THE GASKET SEALING SURFACE DAILY WITH MILD
DETERGENT TO REMOVE HARMFUL FOOD ACIDS. TURN
HANDWHEEL COUNTER-CLOCKWISE TO RETRACT GASKET PLATE
FULLY INTO DOOR WHEN NOT IN USE. DAMAGE TO GASKET
SEALING SURFACE, SUCH AS NICKS OR CUTS WILL CAUSE STEAM
LEAKAGE.
Item B: A Thrust Screw is located inside the door and its shaft protrudes through the door centre and is
fastened directly to the Handwheel. Any force on the Handwheel is transmitted through the Thrust Screw
simultaneously against the Gasket Retaining Plate and Door Gasket to seal the compartment.
THE THRUST SCREW OF EACH COMPARTMENT DOOR SHOULD BE
LUBRICATED ONCE A MONTH. TO GAIN ACCESS TO SCREW, OPEN
COMPARTMENT DOOR AND TURN HANDWHEEL CLOCKWISE (CLOSE
DIRECTION) UNTIL GASKET RETAINING PLATE IS FULLY EXTENDED OUT
OF DOOR. GRASP FINGER HOOKS AND LIFT UP AND OUT TO REMOVE
GASKET PLATE ASSEMBLY. APPLY GREASE NLG12 CONSISTENCY OF
285W60 VISCOSITY LIBERALLY TO THRUST SCREW ROTATING HAND-
WHEEL TO ASSURE COMPLETE COVERAGE. REPLACE GASKET PLATE
AND TURN HANDWHEEL COUNTER-CLOCKWISE RETRACTING GASKET
PLATE INTO DOOR. CLOSE DOOR.
Item C: A Compartment Vent is plumbed to each compartment directly behind the Cooker Control Enclosure.
During preheat or initially at commencement of cooking operation it remains open to exhaust air and
condensate from the compartment. It will close at approximately 180°F.
Item D: A Timer is fastened to the Cooker Control Panel for each compartment and can be dialed from 0 to 60
minutes. At completion of the cooking cycle, dial should read '0' and an audible Buzzer will commence and
can only be silenced by releasing the Operating Handle.
Item E: A Pressure Relief Valve is located inside the Control Enclosure and is plumbed to the top of the Steam
Header. This protective device will open when 8 p.s.i. steam pressure is exceeded. Replace if leakage occurs
or it opens below rated pressure.
13
Содержание CSC-24S
Страница 10: ...PERIODIC MAINTENANCE SECTION 4 MODELS SC 2 SC 3 8 FIG 2...
Страница 14: ...PERIODIC MAINTENANCE SECTION 4 MODELS SC 2 SC 3 FIG 3 12 EXHAUST TO DRAIN STEAM IN...
Страница 25: ...PARTS LIST SECTION 7 COMPARTMENT DOOR ASSEMBLY FIG 4 23...
Страница 28: ...PARTS LIST SECTION 7 MODELS SC 2 SC 3 COOKER ASSEMBLY FIG 5 25...
Страница 30: ...PARTS LIST SECTION 7 COOKER CONTROLS FIG 6 27...
Страница 32: ...PARTS LIST SECTION 7 GENERATOR CONTROL BOX ASSEMBLY FIG 8 29...
Страница 34: ...PARTS LIST SECTION 7 GENERATOR ASSEMBLY FIG 5 31...
Страница 36: ...PARTS LIST SECTION 7 CABINET FIG 9 33...
Страница 38: ...WIRING DIAGRAM MODELS SC 2 SC 3 SECTION 8 35...
Страница 39: ...WIRING DIAGRAM MODELS EDA 2 SCDA 2 GDA 2 DDA 2 SUPPLEMENT SECTION 9...