SERVICE INFORMATION

 

SECTION 6: 

       MODELS: SC-2 & SC-3

 

COOKER PROBLEMS  (cont'd) 

Water enters compartment through Steam Solenoid Valve 

If the cooking cycle is on and water enters compartment through valve and 

steam pressure is nonexistent, then this may indicate malfunction of the 

Water Level Control (in Cabinet).  The switch in the Water Level Control may 

be defective and remain in the closed position, consequently energizing the 

Boiler Water Supply Valve to continuously supply water to fill the Heat 

Exchanger, Steam Header and eventually overflow into the compartment(s) 

through Steam Solenoid Valve(s). 

However, a more likely cause is excessive sealant and/or lime build up 

within the chamber of the Water Level Control, which having formed around 

the float, prevents it from fluctuating upwards with the increase in water 

level and thus the float is unable to trip the switch in the control to de-

energize the solenoid valve and consequently stop water from being fed to 

the Heat Exchanger and flooding the system.  Refer to Heat Exchanger on 

Removal of Sealants, etc..  This malfunction is extremely serious and 

indicates that water quality is inadequate and must be rectified immediately 

with a proper water conditioner. 

Pressure Relief Valve leaks or opens frequently 

This valve sits on top of the Steam Header and assures that pressure will 

not exceed 8 p.s.i..  The valve may leak if dirt is under valve disc.  

Manually trip lever of valve smartly a few times in an effort to dislodge 

and blow dirt away.  Pressure Gauge on Cooker Control Panel should read 

maximum 6 p.s.i. and if valve continues to leak, then it is defective and 

must be replaced. 

Pressure in Steam Header may be too high and Pressure Regulating Valve will 

require adjustment.  To readjust, loosen lock nut on the adjusting screw and 

turn adjusting screw counter-clockwise to decrease pressure. 

19

 

Содержание CSC-24S

Страница 1: ...d or electrical cooking equipment then the terms and conditions of the Manufacturer s Limited Warranty will be rendered void and no warranty of any kind shall apply If the equipment has been changed a...

Страница 2: ...Operating Instructions 15 SECTION SIX SERVICE Service Information 16 SECTION SEVEN PARTS Parts List 23 SECTION EIGHT WIRING Wiring Diagrams 35 CAUTION WATER QUALITY IS THE MAJOR FACTOR AFFECTING THE P...

Страница 3: ...not be liable for consequential or special damages of any nature that may arise in connection with such product or part Should service be required at times which normally involve overtime or premium l...

Страница 4: ...s i EC Electrical Connection 120 Volts 60 Hertz single phase with grounding wire required unless otherwise specified DR Boiler and compartment drain approx 2 in diameter Provide open air gap type dra...

Страница 5: ...erate satisfactorily Therefore a Model SC 2 requires 2 BHP and a Model SC 3 requires 3 BHP Assuming availability of 30 p s i supply steam pressure immediately to the appliance then pipe sizes of 1 2 3...

Страница 6: ...mately 32 p s i from an original Boiler supply of 40 p s i It is suggested that wherever possible the steam supply line to the appliance be a separate line from the steam source If the appliance must...

Страница 7: ...becomes an entirely sealed chamber The duration of the cooking cycle is controlled by the Timer and when desired time has elapsed Timer will read 0 and will set off an audible Buzzer and de energize...

Страница 8: ...pans since steam circulation between pans in the compartment will be impeded Always preheat compartments for satisfactory results When a11 compartments are to be used at the same time allow one compa...

Страница 9: ...hell Solid 7 8 4 6 Eggs in 2 1 2 2 3 3 dozen 1 3 Shell Perforated 4 6 4 6 Fish Fillets 2 1 2 8 12 3 1 3 Perforated 10 15 4 6 Meatloaf 2 1 2 35 40 15 1 3 Solid for Broth 40 45 4 6 Peas 2 1 2 6 7 5 1 3...

Страница 10: ...PERIODIC MAINTENANCE SECTION 4 MODELS SC 2 SC 3 8 FIG 2...

Страница 11: ...within the chamber of the Water Level Control and when it drops it will trip the switch in the control and demand sufficient water to replenish it to the proper level A MANUAL VALVE LOCATED DIRECTLY...

Страница 12: ...ght is located directly above the Power Switch and when lit green indicates power is ON Item L Operating Pressure Switch is fastened to the inside bottom front of the Generator Control Box and is plum...

Страница 13: ...l consequently set off this valve ONCE A WEEK THIS VALVE SHOULD BE TRIPPED DURING OPERATION TO ASSURE THAT IT FUNCTIONS PROPERLY Item R Pressure Regulator reduces the pressure of the steam supplied fr...

Страница 14: ...PERIODIC MAINTENANCE SECTION 4 MODELS SC 2 SC 3 FIG 3 12 EXHAUST TO DRAIN STEAM IN...

Страница 15: ...IN ACCESS TO SCREW OPEN COMPARTMENT DOOR AND TURN HANDWHEEL CLOCKWISE CLOSE DIRECTION UNTIL GASKET RETAINING PLATE IS FULLY EXTENDED OUT OF DOOR GRASP FINGER HOOKS AND LIFT UP AND OUT TO REMOVE GASKET...

Страница 16: ...TOM A stainless steel strainer is provided in each compartment just ahead of the exhaust port as a protective device for this valve Remove clean and replace if excessive food and or dirt accumulation...

Страница 17: ...dwheel clockwise sufficiently to provide a good seal on gasket Set Timer to desired cooking cycle Pull out Operating Handle and set in position Pilot light will indicate that cooking cycle is now in p...

Страница 18: ...turn Foreign matter or lack of lubricant on dry Thrust Screw may cause threads to bind Refer to Section 4 Periodic Maintenance If Thrust Screw is bent or threads are badly worn remove Thrust Screw and...

Страница 19: ...e may be incapable of opening Since this valve contains a moveable blade and when de energized the blade reacts as a guillotine which should be free to move fully down into the valve pocket projection...

Страница 20: ...et is ON and steam pressure reading shows 5 to 6 p s i on Pressure Gauge of Cooker Control Panel and all compartments fail to function for the cooking cycle then power obviously is not being supplied...

Страница 21: ...thus the float is unable to trip the switch in the control to de energize the solenoid valve and consequently stop water from being fed to the Heat Exchanger and flooding the system Refer to Heat Exch...

Страница 22: ...ch or slotted screwdriver will lower the pressure settings Refer to Periodic Maintenance Section 4 for proper pressure settings Each nut should be turned slightly and the pressure reading on the Gauge...

Страница 23: ...efer to Heat Exchanger on Removal of Sealants etc for proper procedure Heat Exchanger achieves pressure slower than normal If the Heat Exchanger requires considerably more time than 25 minutes to achi...

Страница 24: ...ight Unplug and or uncap all pipe fittings and allow solution together with sealant to drain out During the procedure exercise extreme care to avoid personally coming in contact with the acid If conta...

Страница 25: ...PARTS LIST SECTION 7 COMPARTMENT DOOR ASSEMBLY FIG 4 23...

Страница 26: ...placement parts may be ordered either through a Southbend Authorized Parts Distributor or a South bend Authorized Service Agency When ordering parts please supply the Model Number Serial Number Part N...

Страница 27: ...8 1181 Alignment Screw 2 9 1 69C0 Nut 2 10 8 1182 Thrust 8ar 1 11 8 1183 Thrust Screw 1 12 2 W186 Hasher 1 13 8 1184 Compartment Door 1 14 8 1187 Bronze Bushing 2 15 1 T6S8 Tension Pin 2 16 8 1188 Hi...

Страница 28: ...PARTS LIST SECTION 7 MODELS SC 2 SC 3 COOKER ASSEMBLY FIG 5 25...

Страница 29: ...03 Microswitch 2 12 1 S7C4 Miroswitch Spacer 2 13 2 11C9 Microswitch Screw 2 14 3 CV42 Compartment Vent 1 15 3 S467 Exhaust Solenoid Valve 1 16 3 2200 Brass Nipple 2 17 3 U4BE Union Elbow 2 18 3 S422...

Страница 30: ...PARTS LIST SECTION 7 COOKER CONTROLS FIG 6 27...

Страница 31: ...nstruction Label 2 comp 1 or 8 1205 Cooker Instruction Label 3 comp 1 7 3 PG15 Pressure Gauge 1 8 3 15PG Gauge Fastening Bracket 2 9 1 39CO Pressure Gauge Nut 2 10 1 59CO Enclosure Fastening Nut 2 com...

Страница 32: ...PARTS LIST SECTION 7 GENERATOR CONTROL BOX ASSEMBLY FIG 8 29...

Страница 33: ...t Screw 2 3 4 70EU Ground Terminal 1 4 4 LQE7 Liquid Tite Elbow Assembly 4 5 8 1244 Control Box Cover 1 6 1 33C3 Cover Bolts 4 7 3 S162 Solenoid Valve 2 8 1 23C3 Terminal Block Screw 4 9 4 22T8 Termin...

Страница 34: ...PARTS LIST SECTION 7 GENERATOR ASSEMBLY FIG 5 31...

Страница 35: ...Pressure Regulator 1 4 8 1254 Steamer Drain Assembly 1 5 8 1255 Exhaust Drain Assembly 1 6 3 WG20 Water Gauge Assembly 1 7 3 TST1 Thermostatic Steam Trap 1 8 3 TST3 Thermostatic Steam Trap 1 9 3 S567...

Страница 36: ...PARTS LIST SECTION 7 CABINET FIG 9 33...

Страница 37: ...less Back 1 2 8 1305 Side Panel 2 3 8 1308 Flanged Adjustable Foot Rear 2 4 5 FS64 Adjustable Foot Insert Front 2 5 5 MC02 Magnetic Door Catch 2 1 11C2 Magnetic Door Catch Screws 8 6 8 1303 Right Hand...

Страница 38: ...WIRING DIAGRAM MODELS SC 2 SC 3 SECTION 8 35...

Страница 39: ...WIRING DIAGRAM MODELS EDA 2 SCDA 2 GDA 2 DDA 2 SUPPLEMENT SECTION 9...

Страница 40: ...ervice may be necessary to extend the useful life of this unit When service is needed contact a Southbend Authorized Service Agency or your dealer To avoid confusion always refer to the model number s...

Отзывы: