BrewBlast™ 70CPH O&M
South-Tek Systems
18
6.
Wash the bowls in soapy water and rinse thoroughly as needed. Use of light air gun to remove debris is
also acceptable. Make sure to always wipe down with a clean and dry cloth.
7.
Install new filter element and replace O-rings as needed.
8.
Put the filter bowls back on the system in reverse order of how it was removed making sure the bowl is
seated in place correctly. Only tighten metal casing around filter bowl hand tight.
9.
Be sure to utilize the filter replacement schedule on the face of
the filter bracket to keep track of when the filter was replaced
last.
10.
Put the front cover back on the cabinet and the unit can be
powered up again. Once powered up, you should hear the air
compressor turn on and the
BrewBlast™ 70CPH will resume
producing nitrogen.
Proper cleaning
In beverage, restaurant and pub applications this product is certified as
an NSF product. To ensure compliance with typical requirements of
these environments the product should be cleaned with mild detergent.
Specific to BrewBlast™ BrewBlast™ 70CPH models ensure that the
lower support channel is clean. Clean with approved kitchen cleaner,
apply a rag or brush through the openings as shown with arrows. Keep
free from foreign objects, dust, debris and vermin.
Содержание 70CPH
Страница 4: ...BrewBlast 70CPH O M South Tek Systems 4 Notes...
Страница 12: ...BrewBlast 70CPH O M South Tek Systems 12...
Страница 13: ...BrewBlast 70CPH O M South Tek Systems 13 Optional Separate N2 Storage Tank Setup...
Страница 19: ...BrewBlast 70CPH O M South Tek Systems 19...
Страница 22: ...BrewBlast 70CPH O M South Tek Systems 22 Last Page...