TECHNICAL SPECIFICATIONS

Overall Dimensions: 1.55” H x 4.67” W x 0.98” D

Input Voltage Range:

10 - 30 Vdc

Current Consumption:

0.75 Amps max / module
(flash pattern dependent)

# of LEDs:

 6 Generation 3 LEDs

Light Sync Technology:

Yes

Operating Temperature:

-40º to +65º C

Cruise Light Mode:

Yes

EGHSTE5(xx)  07.14 

4.28

1.19

R0.23

3.81

0.72

Flash Patterns

Pattern Name

FPM

(Flashes per Minute)

1. Single

125

2. Double

125

3. Triple

123

ONE (1) LIGHT

Single Light Operation: Follow the ID Selection steps and set the ECE 

GHOST to ID#1 if it is not already.

TWO (2) LIGHTS

ALTERNATING:

 To obtain Alternating patterns, follow the ID 

SELECTION steps and set one ECE GHOST to ID#1 and the other to 

ID#3.  Then proceed to the PATTERN SELECTION steps. 

SIMULTANEOUS: 

To obtain Simultaneous patterns, follow the ID 

SELECTION steps and set both ECE GHOST lights to ID#1. Then 

proceed to PATTERN SELECTION steps. 

SLAVE MODE

The GHOST is capable of being activated through the use of a use sup-

plied flasher by putting it in slave mode.
1. Permanently connect the GHOST WHITE and BLACK wire to a good, 

convenient ground.
2. Connect the GHOST RED wire, through a 5Amp fuse, to the output of a 

+10-30 Vdc switching flasher.

PATTERN RESET

1.  Remove power

2.  Place WHITE (sync) wire to ground

3.  With sync wire grounded, re-power RED wire

4.  Maintain for one second (light will dim)
5.  Remove power and ground (pattern 1 set)
   

ECE GHOST Sync Configuration Instructions

IMPORTANT! A MAXIMUM OF 4 SINGLE LIGHTS

CAN BE SYNCED TOGETHER

1.  Set ID#

  a.  Identify which pattern and sequence you want and look up ID# 

settings at right.

  b. Connections

  i. RED: 

+12Vdc

    ii.  WHT: +12Vdc (Note: you will need to disconnect after  

     

power is applied)

  iii. BLK: 

Ground

  c.  Apply power to unit

  d.  Without disconnecting power from unit, disconnect WHT  

  wire

  e.  Momentarily connect WHT to Ground to change ID #

    i.  Identify ID# by number of sequential flashes 

    ii.  Possible ID#s: 1 – 4

  f.  Disconnect power from unit to get out of ID mode.

2.  Set Pattern

  a.  Reapply power to units.

  b.  Once all Light Head ID#s are configured, make sure all    

    lights are flashing the same pattern

  c.  Connect corresponding colored wires of all units together:  

    RED to RED, etc.

  d.  Change Pattern

    i.  Momentarily touch WHT wires to Ground

    ii.  Observe pattern change on all lights connected

  e.  Insulate all wires by taping with electrical tape

3.  Connect Master Switch for Application

  a.  IMPORTANT! Ensure WHT Pattern/Sync Wires are tied    

  together

1  Cut hole in sheet metal

2  Press gasket into hole

3  Make wiring connections

4 Test
5  Install light

NOTE:

 

The GHOST is a factory sealed unit that CANNOT be serviced 

in the field. Any attempt to gain access to the GHOST unit will 

most likely cause permanent damage and void its warranty.

RECESS MOUNT ECE65 CERTIFIED 

w/ STANDARD LENS

SINGLE LIGHT

EGHSTE5(x)B - Black

EGHSTE5(x)W - White

EGHSTE5(x)C - Chrome

RECESS MOUNT ECE65 CERTIFIED

w/ XYLEX LENS

SINGLE LIGHT

EGHSTE5(x)B-EU - Black

EGHSTE5(x)W-EU - White

EGHSTE5(x)C-EU - Chrome