background image

Circuit 

Symbol 

Cl 

C2 

C3 

C4 

cs 

C6 

C7 

cs 

C9 

CIO 

Cll 

C12 

C13 

Cl4 

Cl5 

Cl6 

Cl7 

Cl8 

C20 

Diodes 

CR! 

Cll2 

CHJ 

CH4 

CR5 

CH.6 

CH7 

CI:.8 

CH9 

Cl<IO 

CHll 

cn12 

<'l03 

CUl4 

Clll5 

(;1{[6 

CHl7 

CHIS 

CIU9 

c1,20 

CH21 

CH22 

Description 

Capacitors  (Uf  unless  noted) 

50,  50V 

200,  25V 

0.0033,  200V 

0.01,  200V 

0.015,  250V 

0 ,47,  IOOV 

0.1,  IOOV 

15,  20V 

15,  20V 

4.7,  IOOV 

50,  50V 

0.068,  250V 

0.01,  250V 

3.3,  20V 

6.8,  35V 

1.0,  100V 

22,  35V 

6.8,  25V 

47,  20V 

IN4745A 

S12 

S12 

IN825 

IN4747 A 

SIZ 

S12 

S12 

S12 

S12 

S12 

S12 

Sl2 

512 

S12 

$12 

1N4745A 

Sl2 

S12 

S12 

S12 

IN5235U 

Sorensen 

Part  Number 

235-7404P22 

24-2472 

24-2409-4 

24-2409-7 

24-2015-3 

24-2037-15 

24-2037-7 

586385-5 

586385-5 

235-7440P3 

235-7440P22 

24-2015-11 

24-2015-1 

586058-13 

586058-17 

24-2037-19 

586058-23 

235-7395P64 

i35-7395P5G 

588102-IZ 

587565-2 

587565-2 

588105-3 

588102··13 

587565-2 

587565-2 

587565-2 

587565-2 

587565··' 

587565-·2 

587565-2 

587565-2 

587565-2 

587565-2 

587565-2 

588102-1:::: 

587565-2 

587565-2 

587565- 2 

587565-2 

588101-10 

Circuit 

Symbol 

Diodes 

CH23 

CH24 

Iuteg:riited  Circuits 

!Cl 

IC2 

IC3 

IC4 

IC5 

Transistors 

QI 

Q2 
';3 

Q4 

Q5 

Q6 

Q7 

Q8 

Table  6-1 

Replaceable  Parts  List 
DCR-lJ  PCB  Assembly 

Description 

IN943A 

S12 

741 

723 

741 

741 

723 

2N2907 A 

2N2219A 

2N2907 A 

2N2907 A 

H!2907A 

2N2222A 

::N2907A 

2N2222A 

Resistors  (ohms,  1/2  watt  �10%  unless  noted) 

I<! 

330,  3\/  ±5% 

R2 

3.91s. 

R3 

12K 

K4 

6.65K  1/8\'/  ±1% 

RS 

6.65K  1/8W  ±ti 

R6 

649  l/8W  ±!!i, 

R7 

2' 

kB 

10 

m, 

,1 

HIO 

47 

HI! 

330 

Hl2 

12I� 

Rl3 

391..: 

814 

39K 

lil5 

22K 

f.16 

3.3K 

Hl7 

5.6K 

HIS 

680 

Hl9 

1.8K 

1(20 

180 

H.21 

1.2K 

H22 

1.2K 

H23 

I.BK 

R24 

1·.sK 

Sorensen 
Part  Number 

588105-7 

587565-2 

586372-3 

586062-1 

586372-3 

586372-3 

586062-1 

386-n49P58 

386-72

1

l9P32 

386-7249PS8 

386-7249P58 

386-72'19P58 

386-7249P57 

386-7:!49P58 

386-7249P57 

27-397-85 

280-11•15P95 

280-1145Pll3 

586055-188 

586055-188 

586055-65 

280-ll 45Pl4 

280-7176Pl 

280-1145P25 

280-1145P25 

280-1145P56 

280-1145P113 

:!80-1145Pl31 

280-1145Pl31 

280-1!45P!22 

280-· l l 45 P92 

280-1145PIOI 

,80-1145P68 

280-1145P83 

280-1145P47 

280-1145P77 

280··1145P77 

�80-1145P83 

280-1!45P83 

Circuit 

symbol 

pescriµtion 

Resistors  (ohms,  1/2  watt  !10%:  unless  noted) 

R25 

10.0K  1/811  ±1% 

E26A  (IOV) 

lOK  ±1% 

R26A  (20V) 

20K  ±1% 

R26A  (40V) 

40K  ±1% 

R26A  (60V) 

60K  ±1¥, 

R26A  (80V) 

SOK  !'1% 

R26A  (150V) 

150  ±l'il 

R�f.ill 

150K  ±1% 

R26C 

150K  ±1% 

R26D 

!SOK  ±1% 

R26E 

!SOK  ±1% 

R26F 

150K  ti% 

R28 

6.66K  1/SW  ±1% 

H29 

53.6K  t/SW  ±1% 

R30 

!OK  Var 

R31 

4.7K 

R32 

4. 71( 

R33 

270K 

R34 

47K 

R35 

150 

R36 

lOOK 

R37 

101. 

R38 

330K 

R39 

620  21'/ 

R40 

330K 

R41 

39K 

R42 

2.7K 

R43 

1K 

R44 

56K 

R45 

!OK  VAR 

R46 

9.09K  l/8W  !"!% 

R47 

2.15K  I/SW  ±Ii 

R48 

9.09K  1/8W  "t1% 

R49 

2.05K  I/SW  ti% 

R50 

47K 

RSI 

487  l/8W  ±1% 

1{52 

1K 

R53 

200  1/21>  VAR 

1!54 

5.0K  1/211  VAR 

R55 

4.7K  l/4W 

R56 

330  1/4W 

Transformer 

Tl 

Pulse 

!\lis<:cllancous 

Printed  Circuit  noard 
Ass'y 

PCB  Connectors 

Tll-3 

11  Tc1•minol  Strip 

J2 

AC  lnputs 

J3 

IJC  I11puts 

J4 

DC  Inputs 

Rev  D  (9/85) 

Sorensen 
Part  Numbei-

586055-122 

588078cl 

588078-2 

5880'18-3 

588078-4 

588078-5 

588078-6 

588078-6 

588078-6 

588078-6 

588078-6 

588078-6 

586055-119 

586250-157 

586370-16 

280-1145P98 

280-1145P98 

280-1145P16! 

280-1145Pl34 

280-1145P44 

280-1145Pl46 

280-1145Pll0 

280·-ll45Pl64 

280-l147P66 

280-1145Pl64 

280-1145Pl31 

280-1145P89 

280-1145P74 

280-1145Pl37 

586370-16 

586055-120 

586055-90 

586055-120 

586055-89 

280-l145Pl34 

586250-59 

280-ll45P74 

586370-11 

586370-15 

585108-43 

585108-79 

586897-·1 

588176-9 

·-

586971-1 

586288-6 

586288-6 

586288-6 

6-3

Содержание DCR10-40B

Страница 1: ...ion Man 10 408 20 258 40 1 60 1986 by Sorensen Division of Elgar Electronics Corporation This document contains information proprietary to Sorensen Elgar Electronics Corporation The information contai...

Страница 2: ...n no circumstance be liable for any direct indirect special penal or consequential loss or damage of any nature resulting from the malfunction of the product Remedies under this warranty are expressly...

Страница 3: ...g Unit Shutdown Ch cuit Protection Features Page 1 1 1 1 1 1 1 1 1 2 1 2 1 2 1 2 1 2 1 2 OPTIONAL MODIFICATIONS 1 3 SPECI1 ICATIO NS 1 4 INSTALLATION GENERAL 2 1 INITIAL INSPECTION 2 1 ELECTRICAL INS...

Страница 4: ...ions UNIT SHUTDOWN CIRCUIT OVP 3 7 1 3 7 2 OVP Adjustment Cautions THEORY OF OPEHATION INTRODUCTIOl PHASE CONTROL PRINCIPLE BLOCK DIAGRAM ANALYSIS DETAILED CIRCUIT DESCRIPTION 4 4 1 4 4 2 4 4 3 4 4 4...

Страница 5: ...mit Settings PERFORMANCE 1 ESTING Page 5 1 5 1 5 1 5 1 5 2 5 3 5 5 1 5 5 2 5 5 3 Voltag e Mode Regulation and Ripple 5 3 Current Mode kegulation 5 4 Transient Response 5 4 HI POT TEST PROCEDURE DRAWIN...

Страница 6: ...Connections Remote Sensing Master Slave Connections Series Operation Phase Control Firing Angles DCR B Functional Block Diagram Passing Stage Principle Performance l est Setup DCR B PCB Schematic Dia...

Страница 7: ...s Series Connected Recommended Rectifiers Series Ope1 ation DCR D Troublesl1ooting Sensing Resistor Vulues Current Mode Regulation Check lJnit Calibration Specifications H placcable Parts List DCR D P...

Страница 8: ...CR s Silicon Controlled Rectifiers or Triacs at the input to the transformer followed by a passive LC filter This design allows for a wide range of output voltages simplicity of design and offers larg...

Страница 9: ...provide Using a master slave ap proach a maximum of four units can be connected in parallel An alternate method is direct paralleling With this approach there is no limit to the number of units which...

Страница 10: ...he output voltage to zero See details in Section 3 1 3 OPTIONAL MODIFICATIONS The standard DCR B unit is designed for operation from a nominal 115 Vac input however units may be purchased factory modi...

Страница 11: ...input COMMON SPECIFICATIONS Voltage Mode Regulation 0 03 with load change NL to FL or FL to NL and a full line voltage change combined Resolution 0 05 of Eo max typical Drift Eo max 0 1 typical for 8...

Страница 12: ...on indicating lights 5 Alternate power switch between ON and OFF Action should be both positive and audible Return switch to OFF position 6 Remove rear cover and check terminal board Make sure that l...

Страница 13: ...clockwise turn COARSE and FINE CURRENT controls fully clockwise 3 Set unit power switch to ON with zero load current 4 Turn COARSE VOLTAGE control slowly clockwise while observing the unit voltmeter T...

Страница 14: ...and loss of current limiting can result from loosening or removing links on rear mounted terminal board TB3 This may result in personnel injury and damage to equip ment Do not remove or loosen any li...

Страница 15: ...variations in the output voltage or current VOLTAGE mode indicator A red light which illuminates when the unit is DS2 operating in the voltage regulating mode Panel voltmeter Ml A meter connected inte...

Страница 16: ...ing Resistance Remove jumper 5 6 connect program resistor between 4 5 Voltage Remove jumper 3 4 connect signal O lOV to 3 positive return to 1 Variable reference output 0 lOV cG Error Amplifier Input...

Страница 17: ...minals Replace cover 7 Set unit power to ON and turn CURRENT control to the desired cur rent limiting value POWER light will illuminate and the unit is in voltage mode operation NOTE With unit in the...

Страница 18: ...0 to 600 Vdc models Note that a heavy pulse load can act the same as a momentary load short and may damage the amplifier under remote sense conditions Consult the factory for recommendations if you in...

Страница 19: ...lus sense and minus sense terminals to the load Observe Polarity To reduce stray pickup use shielded cable shield grounded at the supply or a twisted pair of wires for sensing leads Replace the rear a...

Страница 20: ...als 4 and 5 Figure 3 5 Use shielded or twisted wire for interconnecting leads 3 Rotate COARSE and FINE VOLTAGE controls fully counterclockwise 4 5 Operation Set POWER switch to ON Rotate CURRENT contr...

Страница 21: ...utput is regulated at the value deter mined by the setting of the current controls The output voltage varies as a function of load To operate unit in the current mode proceed as follows 1 Rotate FINE...

Страница 22: ...1 0 milliampere TB 1 Figure 3 6 Current Mode Programming Connections To adapt unit to the current mode resistance programming configuration proceed as follows 1 With unit power OFF remove the link be...

Страница 23: ...ected and twisted wires should be used for the interconnecting leads For a full range variation in unit output current signal must have O to 400 mV volt range Terminal 8 is positive 3 3 3 CAUTION Do n...

Страница 24: ...e DCR B panel voltage control fully clockwise or to desired volt age limit 4 Short the DCR B output terminals and apply DCR B input power 5 Set zero current adjust potentiometer R53 on the DCR B PCB t...

Страница 25: ...ned but only four units may be paralleled with the direct method there is no limit to the number of units which may be paralleled and no current derating is required Output voltage regulation however...

Страница 26: ...ections Master Slave Paralleling Figure 3 9 To connect two units in parallel proceed as follows NOTE Up to three slave units may be added by ex tending this procedure 1 With no load applied set master...

Страница 27: ...y 3 5 3 5 1 Figure 3 9 Master Slave Connections Parallel Operation SERIES OPERATION Direct Series Connections Figure 3 10 DCR B supplies may be directly series connected up to a total output of 200 Vd...

Страница 28: ...be connected across the output terminats of each unit as shown in the figure This will prevent damage to the output capacitors Spe cific rectifier types are listed in Table 3 3 4 Set unit power switch...

Страница 29: ...s are to be used consult factory for connecting dissimilar units connect as shown in Figure 3 11 RA and RB are low TC wire wound resistors of 5 watts rating or greater Resis tance values for two ident...

Страница 30: ...N4587R 20 25B 1Nll83 1N1183R 40 13B MR1121 MR1121R 60 9B MR1121 MR1121R 80 6B MR1122 MR1122R 150 3B 3S12 2 300 1 5B 3S14 2 600 75B 3S18 2 i Reverse polarity rectifiers flat aluminum plate Operation So...

Страница 31: ...sense terminal 1 of TB3 This connection may be metallic reed relay or wire or may be a transistor or optical coupler The device must sink approximately 2 mA from terminal 11 such that pin 11 drops bel...

Страница 32: ...n requires protective diodes See Figure 3 8 and 3 9 CAUTION If the DCR B is used with an energy storage type of load e g batteries or large capacitor or inductor banks protective diodes must be used i...

Страница 33: ...Figure 4 1 represents normal ac line voltage If by some means conduction of this voltage is delayed the average voltage output will be reduced Control of the delay then results in control of the aver...

Страница 34: ...CR8 ETC MAIN ASSEMBLY COMPONENTS 7rR FILTER LI R3 R5 I C V MODE INOi CATOR C C MODE IND CATOR VARIABLE REFERENCE IC3 C V ERROR AMPLIFl ER IC2 C C ERROR AMPLIFlER IC5 TURN ON CIRCUIT Q6 Q8 t SHUTDOWN C...

Страница 35: ...utput across Rl7 sets the conduction angle of blocking oscillator Q2 The duration of Q2 conduction is directly proportional to the error signal and its output trig gers CR into conduction CR7 acts as...

Страница 36: ...n gated through CR6 and filtered by C2 to provide the 20 Vdc primary operating power for the control PCB CR23 and R51 utilize the 16 Vdc derived from R35 and CRl7 to gen erate and precisely regulate t...

Страница 37: ...nents from overstress Trimmer R53 is used to adjust zero output current compensating for current tolerances and offset voltage of ICS Trimmer R54 is used to adjust for maximum current setting compensa...

Страница 38: ...as follows When power is initially applied to the unit the bases of Q6 Q8 are driven positive due to Cl0 coupling the rising voltage of Vee Q6 and QB are thus in saturation The resultant negative volt...

Страница 39: ...bar on To reset the OVP power must be removed from the power supply input After a moment to reset lower the output voltage control and reapply power to the in put 4 4 9 Indicator Lamps DSl which indic...

Страница 40: ...n symptoms along with a tabulation of the possible cause s for each symptom Note that the failure of a single component may result in a chain reaction effect As additional aids to troubleshooting volt...

Страница 41: ...put voltage mode Fuse opens or circuit breaker trips High output voltage meter pointer pegs No output current mode or unit will not current limit Output oscillates current mode a Wrong input voltage b...

Страница 42: ...d by the terminal screws Alligator clips and similar types of connectors are not suitable Grounding tech niques in which more than one device in the setup is grounded may introduce extraneous ripple t...

Страница 43: ...regulation proceed as follows 1 2 3 4 5 5 5 3 At no load adjust output to maximum rated voltage and set COARSE CURRENT control fully clockwise Connect a sense resistor Table 5 2 or a prec1s1on meter s...

Страница 44: ...Check DCR MODEL SENSE RESISTOR Ohms 10 40B 0 01 SOW 20 2SB 0 01 sow 40 13B 0 01 SOW 60 9B 0 1 2SW 80 6B 0 1 2SW 150 3B 0 1 2SW 300 1 SB 1 0 lOW 600 75B LO IOW Table 5 3 Unit Calibration Specifications...

Страница 45: ...valent on the highest resistance scale available If it is essential to use the high potential test method please contact the factory for information on special precautions that should be taken Mainten...

Страница 46: ...CAUTION Do not reconnect for these voltages unless parts Per Table 6 2 page 6 17 are also changed Figure 6 12 is the Over Voltage Protector schematic and parts location drawing 6 2 PARTS LIST COLUMN...

Страница 47: ...Rl7 5600 RIZ RQ i2i cs l30 CA6 I TO Tl cu so r FROM CKT 8RK R 1 I I I I I I 0588300 Rev M Parts List Table 6 J NOTES 1 UNLESS OTHERWISE PECIFIEO l t EL EC TRICAL VALUES FOR RESISTORS ARE IN OHMS RE S...

Страница 48: ...372 3 586062 1 586372 3 586372 3 586062 1 386 n49P58 386 721l9P32 386 7249PS8 386 7249P58 386 72 19P58 386 7249P57 386 7 49P58 386 7249P57 27 397 85 280 11 15P95 280 1145Pll3 586055 188 586055 188 586...

Страница 49: ...t I C a ti 1 Ol Ill I Z I VI jl a JI I ID I t I l c Figure 6 2 PCB Component Location Diagram 6 4 Rev B 6 84...

Страница 50: ...cs TB1 C4 Rl3 C6 C7 RI T2 Rl2 F2 p LI P3 A3 P2 RS CAB etc I Tl Figure 6 3 Component Layout Typical Assembly 6 5 Rev B 6 84...

Страница 51: ...8300 I_C4 32 000 CV C C 0S2 l 3 68 6 5W s N UNLESS 0TNEllk lSE SP CIFIEO ALL Rt 51 S roR VALUES ARE tN OIIMS AND ANE 10 2 IJNL SS 0THERWIS SP CIFIE O ALL CAPACITOR VALl S ARE IN MICROl ARADS A ID ARE...

Страница 52: ...CR I INIIB4A ci ls IRs lb RI 2w Rll 80 2W RIO _L_I_ q_llOO q MO Z DW I b6 ooo so JS 3 OUT M2 A l SJ 12 5W J4 8 2S VA l o 1 J 230 Cv 3 I AC VOT S v c c VAC I lB o I t Nl SS 0TH RWl c SPECIFIED ALL l li...

Страница 53: ...30 c i v c L V C X DS2 0S3 PCB SCHEMATIC 588300 r xs 11 0 r 11 000 ml I Jf l Jl 2 srNS S NS Cb t9 0bO I RI 600 Rtl Bo 2W l 10 7 J4 8 X L i 1 0 5 6 S w cR I lt 1184A A OT I UNLESS O rl lERWISE SPECf IE...

Страница 54: ...l 2 0lA 5 0 i T E J 2 2_ S 7 E sw T2 PRi 1 RY Q r J n 1 1 20 8 1 YA VI C YAC tB 0 r j o C VAC L NOTES CRII IM12 0l A f UAllESS 0TH RW SE SPECl 1 O At L 1 S Sl R VAW 5 AR IN OHMSAND ARE IOY 2 UNllSS ar...

Страница 55: ...Ml RY T 2 PRiM RY r Qr n rJ AIOTE S rc 4 Is 4 Uo 4 200 LI R3 3 3 5 b 5W 2oe J l d c v c v c c v c v c 1 l EB1 I U VI ESS OTIIERWtSI SP CIJ ED ALI x S15TOR VAlUES AR IN OHMS N 1 IJk e 10 2 f L SS OTJ R...

Страница 56: ...SCI IE v A TIC 588300 Jl 1 J1 2 SENSE SEtlSE Rli 2w Tl 1 1 14 R1t t 1 1l LiJ o c t __ ___ _ 3Sl4 ___ _ l i 1 CR I JS S 3S 14 6 5W NOT S I UNLESS OTIIERWISE SPECif IED All R SISTOR VALUES ARE IN CHM5 A...

Страница 57: ...Rtt iiSO Rll cR a 21s r1 3516 1 ri f b I re I a I R 10 OUT I I ro f f r C 6f IO x o J 4 SIO Lt b sow Ts o OOVOC G NOI I I f IO 12 I I I 1 I IO 13 OUT I I L J NOTES CR I 3Sl8 R3 22 _ 57 b SW I I IJL S...

Страница 58: ...cs 30 CRIS soJ S t 5w NOT S RS l 5 K 2 w l Sk Z W I UNLE 55 OTHERW 5 P CIFIED AU ll StST ll VALl S ARC IN OHMS AND ARE 0 2 NLESS OTUf RWIS SPli C 1 ll D ALI CAPACITORS VAWE 5 AP IN MICRDJ ARADS 4ND AR...

Страница 59: ...0V 6 500 75V 4 200 100V 1 100 200V 510 400V 230 lOOV 32 000 15V 9 000 25V 11 000 50V 6 500 75V 4 200 lOOV 1 100 200V Not Used 230 100V 110 000 15V 66 000 25V 19 000 50V 6 500 75V 4 200 100V 1 100 200V...

Страница 60: ...X X X X X X X Not Used X 3S18 X X X X X X X Not Used X 3S18 X X X X X X X Not Used X 3S18 X X X X X X X Not Used X 3S18 Lamps X X X X X X X X Power X X X X X X X X Voltage X X X X X X X X Current Fus...

Страница 61: ...8A X Ammeter 0 SA X Ammeter 0 2A X Ammeter 0 lA Resistors ohms 1 2W 10 unless noted X X X X X X X X 1 5K l0W X X X X X X X X 150 2W X 0 68 6 5W 5 X 1 5 12 5W 5 X 1 0 6 SW 5 X 2 2 6 5W 5 X 3 3 6 SW 5...

Страница 62: ...0 01 X 0 016 X 0 031 X 0 045 X 0 067 X 0 135 X 0 275 X 0 540 X X X X X X X X 650 2W Variable X X X X X X X X 80 2W Variable X X X X X Not Used X 0 33 12 5W X 1 5 12 SW X 6 8 12 5W X X X X X X X X Pow...

Страница 63: ...ach X X X X X X X X Output Terminal Board X X X X X X X X Cover Top Bottom 2 Req d X X X X X X X X Cover Access X X X X X X X X Cover Rear X X X X X X X X Case Side 2 Req d X X X X X X X X Handle 2 Re...

Страница 64: ...10 ___ C589308 l REV F 1 T1 1 _ 180 Jl Sw l I 180 l so f j sw cov 1 I GRAY c rq L i EI OuT i y U c r E ro rs 2 iCI i z A A 7 53 I T 3 II To J S 3ov IC Tl l I 2N 22A RB I ce 7 c ur Y 12 77 P o le I Tl...

Страница 65: ...S12 1N5242B 1N753 1N5234B S12 1N4587 SCR 68 6083 SCR 68 6082 SCR 68 6085 S12 SN72710CN 2N2222A Resistors ohms 9 lK 1 4W 11 5K 1 4W 6 8K 1 4W 5 6K 1 4W 2 2K 2W 10 15K 2W Variable 25K 2W Variable SOK 2W...

Страница 66: ...t 17 f4321 INPUT 6FT 3PRONGPLJh8M LG COROWIMOLO ED u Notoc Sllde ad 0P 0 l Z5 0N o Note All d n available o 1se imensions are in inches mm Figure 6 13 DCR B Outline Dr wing 6 21 P S SHUTDOWN Rev D 9 8...

Отзывы: