Remote Shutdown: Sink l mA to
Regulator Common-
- - - - .,...
Internal Current Shunt, Positive.- - - - - - - - - - - - -
@ ,
} Approx. 0.4V for rated
output.
Internal Current Shunt, Negative.- - - - - - - - - -- -- -
0
Current Programming:
Resistance:
Remove jumper 7-8, connect program
resistor between 8-9.
Voltage:
Remove jumper 7-8, connect signal (Pos)
to 8, return to 9.
Voltage Programming:
Resistance:
Remove jumper 5-6, connect program
resistor between 4-5.
Voltage:
Remove jumper 3-4, connect signal
(O-lOV) to 3 (positive), return to 1.
Variable reference output, 0-lOV. - - - - - - - - - - -
-c
G
Error Amplifier Input. - - - - - - - - - - - - - - - -
@
Output Voltage Sense
NEG@
Sense current= 1.0mA (Neg Lead)
= 20� (Pos Lead) (typical)
Load Circuit Burden= .5V/Lead.
(Regulator Common) POS
G)
®<-
sense) is jwnpered to - OUTPUT
Q)(+ sense) is jumpered to+ OUTPUT
..__
'
I
Figure 3-2 Control PCB Barrier Strip Connections
Operation
3-3
CURRENT CONTROL
VOLTAGE CONTROL
(-)
OUTPUT SENSE
(+)
Rev B (6/84)