![Sorensen DCR10-40B Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/sorensen/dcr10-40b/dcr10-40b_instruction-manual_1332743030.webp)
Table 3-2 RA/RB Values--Two Identical
DCR-B Units Series Connected
(V) RATED
RA
RB
10*
Open
Open
20
SK
l0K
40
15K
l0K
60
25K
l0K
80
35K
l0K
150
70K
IOK
300
145K
IOK
600
295K
lOK
*For 10 volt units, terminal 3 of the slave unit is connected directly to
the plus
(+)
sense terminal of the master unit.
Table 3-3 Recommended Rectifiers, Series Operation
DCR
Model
Mfr.-Ty:ee
10-40B
1N4587
1N4587R*
20-25B
1Nll83
1N1183R*
40-13B
MR1121
MR1121R*
60-9B
MR1121
MR1121R;';
80-6B
MR1122
MR1122R*
150-3B
3S12 (2)
300-1.5B
3S14 (2)
600-.75B
3S18 (2)
i.-Reverse-polari ty rectifiers
;';-;';flat aluminum plate
Operation
Sorensen
Heats ink;';-;';
Part No.
Dim. Inches (mm)
587571-1
4
X
4
X
1/8
587571-3
(102)
X
(102)
X
(3)
587382-1
3-1/2
X
3-1/2
X
1/8
587382-6
(89)
X
(89)
X
(3.2)
26-1046-2
2-3/4
X
2-3/4
X
1/8
26-1046-12
(70)
X
(70)
X
(3.2)
26-1046-2
3
X
3
X
1/32
26-1046-12
(76)
X
(76)
X
(.8)
26-1046-4
1-3/4
X
1-3/4
X
1/32
26-1046-12
(44)
X
(44)
X
(.8)
587566-2
None Required
587566-3
None Required
587566-5
None Required
3-17
Rev B (6/84)