20
Settings
4.5. - Tmax S2
4.6. - Priority Storage 2
Switch-off temperature at sensor 2
If this value is exceeded at sensor 2 and the other conditions are also met, then the
controller switches the associated pump and/or valve off. If sensor 2 falls below this
value again and the other conditions are also met, then the controller switches the
pump and/or valve on again.
Priority of Storages S2
This determines the order, in which the storages are charged. If the same priority is set
for 2 storages, the charging is not switched over until charging the active storage is not
possible anymore.
Danger
Temperature values which are set too high can lead to scalding or dam-
age to the system. Scalding protection must be provided by the cus-
tomer!
4.7. -
ΔT Solar S3
4.8. - Tmax S3
4.13. -
Tmax SB (pool)
Settings, see „4.4. - ΔT Solar S (X)“
Settings, see „4.5. - Tmax S2“
Danger
Switch-off temperature at pool sensor
If this value is exceeded at the applicable sensor, the controller switches the associat-
ed pump and/or valve off. If the temperature falls below this value again and the other
conditions are also met, then the controller switches the pump and/or valve on again.
Temperature values that are set too high can lead to scalding or damage
to the system. Scalding protection must be provided by the customer!