4-3-6.
Operating Cursor Next
• The Cursor Next menu enables the user to move the RPN cursor position to the next already-registered RPN
correction point after the present position in the ascending order of the addresses during the manual registration of
RPN.
(If multiple RPN positions have the same address in the ascending order of the Cursor V Position, the RPN cursor
can move to the RPN position in the ascending order of the Cursor H Position.)
4-3-7.
Operating Cursor Prev
• The Cursor Prev menu enables the user to move the RPN cursor position to the next already-registered RPN
correction point after the present position in the descending order of the addresses during the manual registration
of RPN.
(If multiple RPN positions have the same address in the descending order of the Cursor V Position, the RPN cursor
can move to the RPN position in the descending order of the Cursor H Position.)
4-3-8.
Executing Record
• The Record menu enables manual registration of RPN.
• When the Record menu is selected, the Execute and Cancel choices appear. In addition, selecting Execute starts
registration of RPN.
4-3-9.
Executing Delete
• The Delete menu enables manual deletion of RPN.
• When the Delete menu is executed, the RPN registration of a pixel at an address specified by the Cursor H Position
and Cursor V Position is deleted from the RPN data.
• When the Delete menu is selected, the Execute and Cancel choices appear. In addition, selecting Execute starts
deletion of RPN.
4-3-10. Setting Readout Mode
• The CMOS readout method can be set in the readout mode.
• When "Field" is selected, the RPN extends up and down by adding two lines and is displayed. For this reason,
selecting "Frame" makes it easy to locate the RPN position.
4-3-11. Executing Reset
• The Reset menu enables the user to delete the RPN correction point data registered by Auto Detection and Auto
Black Balance after the unit was shipped from the factory.
• The RPN data registered at the factory and the RPN data registered manually cannot be deleted by Reset.
• When the Reset menu is selected, the Execute and Cancel choices appear. In addition, selecting Execute starts reset
of RPN.
RPN manual registration procedure
1.
Set Video Format to HD422 50/1080/59.94i.
PMW-160/PMW-150/PMW-EX260
4-9
Содержание XDCAM PMW-160
Страница 1: ...SOLID STATE MEMORY CAMCORDER PMW 160 PMW 150 PMW EX260 SERVICE MANUAL 1st Edition ...
Страница 4: ......
Страница 8: ......
Страница 10: ......
Страница 30: ......
Страница 38: ...3 Install the removed parts by reversing steps of removal PMW 160 PMW 150 PMW EX260 2 8 ...
Страница 92: ......
Страница 128: ......
Страница 130: ......
Страница 131: ......