2.
Set the lens iris to CLOSE.
3.
Adjust the gain and the black level so that the RPN position can be viewed best.
4.
Set Cursor to On.
5.
Move the crosshair cursor to the RPN to be registered by using Cursor H Position and Cursor V Position.
When the crosshair cursor comes on top of the RPN, the RPN becomes invisible.
6.
Execute the Record menu.
When the Record menu is attempted, if the RPN registration of a pixel fails at a specific address due to a problem
with the small interval between the current and previous registered RPN spots, a message “NG : Adjacent Pixel”
appears.
PMW-160/PMW-150/PMW-EX260
4-10