3-5
WRT-808A (U)
3-2-3. RF Power Output Adjustment
Equipment and Tools
DC power supply
DC output voltage:
+
3.0
±
0.1 V dc
DC ammeter
Power meter (with power sensor)
MM-SMA (J) connector (Part No. J-6402-480-A)
SMA-BNC (J) connector (Part No. J-6402-490-A)
Adjustor (Part No. 7-721-052-81)
Connections
(For connecting the DC power supply, refer to the “Preparations”
on page 3-2.)
Switch and Control Setting
The following setting is to be perform with the channel se-
lect switches (S504 and S505).
Transmitting Channel setting:
U64 model:
65-01 channel (776.125 MHz)
U66 model:
67-01 channel (788.125 MHz)
U68 model:
69-01 channel (800.125 MHz)
RF power output switch (S401): 50 mW
Input LEVEL control (RV101): “
_
60” (0 dB attenuation)
Turn the RV101 clockwise
fully.
Power meter
MM-SMA (J) connector
with SMA-BNC (J) connector
CT401
RV401
CN402
Power
sensor
Procedure
(1) Connect the power meter (with power sensor) to the an-
tenna connector (CN402) with MM-SMA (J) and SMA-
BNC (J) connectors.
(2) Adjust
1
CT401 so that the power meter reading meets
the following specification.
Specification: Power meter reading = Maximum
Adjustment:
1
CT401/RF-90 Board (B side)
(3) Adjust
1
RV401 so that the power meter reading meets
the following specification.
Specification:
Power meter reading = 50
+
15
mW
_
10
Adjustment:
1
RV401/RF-90 Board (B side)
(4) Set the RF output switch (S401) to the “10 mW” posi-
tion, and check that the power meter reading meets the
following specification.
Specification: Power meter reading = 11
±
5 mW