Installation/connection examples
46
Installation/connection examples
If the projector appears to be operating erratically, try to diagnose and correct the problem using the following
guide. If the problem still persists, consult with qualified Sony personnel.
Symptom
Cause
Remedy
The power does not turn on.
The MAIN POWER switch is turned off.
Press the MAIN POWER switch on the projector
(see page 20)
.
The power turns on and
immediately turns off.
There may be an internal problem.
Check the error code in the error code window on
the rear of the projector and consult with qualified
personnel.
Picture does not appear.
If no menu appears, external signal and/
or sync is not input correctly.
Check SYNC SEL in the INPUT SETTING menu
and connect the sync correctly, if necessary
(see
page 34)
.
If no menu appears with no input, there
may be an internal problem.
Consult with qualified personnel.
Picture is too dark.
Contrast is set to minimum.
Adjust the contrast with the CONTR + key
(see page
23)
.
Clamp setting is not correct.
Change the clamp setting in the INPUT SETTING
menu
(see page 26)
.
The input signal is not selected correctly.
Error code “10” appears and
the projector cannot accept
any other command than
channel selection.
The input signal is unstable.
Check the input signal.
Picture is distorted.
Select a correct signal in the INPUT A or INPUT B
option in the SET SETTING menu
(see page 33)
.
If menu appears with no input, sync
connection is not correct.
Check the input signal and sync in the INPUT
INFO menu and connect them correctly
(see page
39)
.