1-7 (E)
UY
A-S90SF
12
(GB)
Maintenance
Cleaning and Replacing the Rubber Roller of the Auto Slide Feeder
Cleaning the rubber roller
If the rubber roller of the auto slide feeder is dirty, slides may clog easily.
Clean the rubber roller regularly with a cloth moistened with water or
alcohol.
Frequent cleaning is required, especially when you use paper slide mounts.
For how to remove and replace the rubber roller, see “Replacing the rubber
roller.”
Replacing the rubber roller
When the rubber roller wears and the blue portion appears, replace it with
the supplied new rubber roller.
1
Remove all slides from the auto slide feeder, and lock the stoppers for
the holder for prescanning and the holder for scanning.
2
Remove the old rubber roller.
1
Open the lid.
3
Remove the
rubber roller.
2
Lift the shaft using
the tab on the rear
of the lid.
While pressing up the tab,
move the stopper to lock.
13
(GB)
3
Insert a new rubber roller and close the lid.
Make sure the top and bottom of the rubber roller are positioned
correctly.
For more replacement rubber rollers, consult your authorized Sony dealer.
Cleaning inside the Slide Carrier
Inside the slide carrier, there are 15 rollers (shaded in the following
figure). Press the tab to open the carrier and wipe the rollers with a cloth
slightly moistened with water.
Cleaning the Cabinet
When the cabinet becomes dirty, wipe it with a cloth moistened with water
or neutral detergent dissolved in water. Do not use benzene, alcohol,
thinner or chemical cloth as these may damage the finish.
Roller (
×
15)
Press the tab to open.
Top
Bottom
1
Insert a new rubber roller.
3
Close the lid.
2
Insert the shaft into the center of the rubber
roller and turn it a little to drop in the slit on
the base.
Shaft