– 69 –
3-2. CONVERGENCE
(1) Horizontal and Vertical Static Convergence
1. Receive DOT HATCH signal adjust [BRT], [PIX] to looks
easily.
2. Set V. STAT Mg, BMC Mg to standard condition.
3. Correct V. STAT Mg.
(Correct vertical lag of R, B-DOT around the center of CRT.)
(Fig.3-5)
4. Adjust BMC Mg.
(Make evenly horizontal lag of R, B-DOT toward G-DOT
around the center of CRT.)
5. Adjust H. STAT VR. (RV701)
(Adjust horizontal lag of R, B-DOT around the center of CRT.)
(Fig.3-5)
6. Have to tracking adjust V. STAT Mg, BMC Mg because DOT
moves influence each other.
(Correct vertical lag of R.G.B.-DOT.)
BMC magnet
Vertical static
convergence magnet
Purity
•
Movement of red, green and blue dots by V. STAT tilting
and opening or closing.
Center dot
Horizontal static
convergence
B
G
R
B
G
R
RV701 (H-STAT)
Vertical static
convergence magnet
Fig.3-5
•
If the blue dot did not harmonize with red and green,
then use the BMC magnet to adjust.
1)HMC (Horizontal mis-convergence) correction
B
G
R
B
G
R
B
G
R
B
G R
B
G
R
B
G
R
1
Movement of opening or closing the
V. STAT convergence magnet.
2
Movement of tilting the V. STAT conver-
gence magnet counterclockwise.
3
Movement of tilting the V. STAT conver-
gence magnet clockwise.
4
Movement of tilting and opening or clos-
ing the V. STAT convergence magnet.
2)VMC (Vertical mis-convergence) correction.
R G B
A = B
A
B
R G B
A
B
R
G B
A
B
R G
B
A < B
A
B
HMC correction (A)
HMC correction (B)
A > B
A = B
VMC correction (A)
VMC correction (B)
C < D
C = D
C > D
C = D
R
G
B
C
D
R
G
B
C
D
B
D
C G
R
R
G
B
C
D
Содержание TRINITRON KV-VF21M70
Страница 78: ... 78 MEMO ...