— 19 —
KV-34FS12T
3-5. METHOD OF SETTING THE SERVICE
ADJUSTMENT MODE
Service Mode Procedure
1. Standby mode (power off).
2. Press
Display
Channel 5
Sound volume
Power
+
on the Remote Commander (press each button within a
second).
Service Adjustment Mode In
1. The CRT displays the item being adjusted.
2. Press
or
on the Remote Commander to select the item.
3. Press
or
on the Remote Commander to change the
data.
4. Press
then
to save into the memory.
Service Adjustment Mode Memory
Turn set off then on to exit service adjustment mode.
service defl hsiz
16
ntsc
vchp 00000000 00000000
Category
Display
Item
Mode
Item
Data
Signal
Type
write
3-4. SCREEN (G2)
1. Input a dots pattern.
2. Set the PICTURE and BRIGHTNESS controls at minimum
and COLOR control at normal.
3. Adjust SBRT, GCUT, BCUT in service mode with an
oscilloscope as shown below so that voltages on the red,
green, and blue cathodes are 170 ± 2.0 VDC.
4. Observe the screen and adjust SCREEN (G2) VR in FBT
to obtain the faintly visible background of dot signal.
3-6. WHITE BALANCE ADJUSTMENTS
1. Input an entire white signal with burst.
2. Set to Service Adjustment Mode.
3. Set the PICTURE and BRIGHTNESS to minimum.
4. Adjust with SBRT if necessary.
5. Select GCUT and BCUT with
and
.
6. Adjust with
and
for the best white balance.
7. Set PICTURE and BRIGHTNESS to maximum.
8. Select GDRV and BDRV with
and
.
9. Adjust with
and
for the best white balance.
10. To write into memory, press
then
.
更多难得资料请到江南家电维修论坛免费下载!