— 15 —
KV-34FS12T
Coated
Earth
Ground
Strap
2-4. PICTURE TUBE REMOVAL
WARNING:
BEFORE REMOVING
THE ANODE CAP
High voltage remains in the CRT
even after the power is disconnected.
To avoid electric shock, discharge
CRT before attempting to remove the
anode cap. Short between anode and
CRT coated earth ground strap.
a
REMOVAL PROCEDURES
HOW TO HANDLE AN ANODE CAP
WARNING: High voltage remains in the CRT even after the power is disconnected. To avoid electrical shock, discharge the CRT before
attempting to remove the anode cap. Short between anode and coated earth ground strap of CRT.
NOTE:
After removing the anode, short circuit the anode of the picture tube and the anode cap to either the metal chassis, CRT shield,
or carbon painted on the CRT.
1
Do not use sharp objects which may cause damage to the
surface of the anode cap.
3
Do not force turn the foot of the rubber cover. This may cause
the shatter-hook terminal to protrude and damage the rubber.
2
To avoid damaging the anode cap, do not squeeze the rubber
covering too hard. A material fitting called a shatter-hook terminal
is built into the rubber.
2
Use your thumb to pull the rubber
cap firmly in the direction indicated
by arrow
b
.
3
When one side of the rubber cap
separates from the anode button,
the anode cap can be removed by
turning the rubber cap and pulling
it in the direction of arrow
c
.
1
Turn up one side of the rubber cap in
the direction indicated by arrow
a
.
b
Anode Button
c
ANODE CAP REMOVAL
6.
Loosen the deflection yoke fixing screw and remove.
7.
Place the set with the CRT face down on a cushion and remove
the degaussing coil holders.
8.
Remove the degaussing coils.
9.
Remove the CRT grounding strap and spring tension devices.
10. Unscrew the four CRT fixing screws [located on each CRT
corner] and remove the CRT [Take care not to handle the
CRT by the neck].
1.
Discharge the anode of the CRT and remove the anode cap.
2.
Unplug all interconnecting leads from the deflection yoke, neck
assembly, degaussing coils and CRT grounding strap.
3.
Remove the CA Board from the CRT.
4.
Remove the chassis assembly.
5.
Loosen the neck assembly fixing screw and remove.
2
3
4
9
8
7
6
5
10
1
更多难得资料请到江南家电维修论坛免费下载!
http://bbs.520101.com