Integrator Training, UK
Confidential
Digital Cinema Deployment
48 of 49
October 15
CHIPS Stand-Alone Integrator Installation Training (CHIPS)
Ignore the “select auditorium” tab
Login
Enter the following details for each auditorium
Auditorium name
Auditorium X
IP Address
<IP of Auditorium X”
Port
443
12.6 Create
Shortcuts
Create a shortcut on the Desktop for the following:
SMSC (if needed)
http://TMS
‐
ServerIP:8400/TMS
‐
Server
Error! Hyperlink reference not valid.
13 Hardware
Test
Procedures
Complete the following tests to check that the CHIPS rack is powered up correctly
and the network connectivity is established.
Hardware Test Procedures
Network Tests
Procedure
Expected Result
If Test Fails
Test
Completed
TMS Server to TMS
Client PC
Open command
prompt on TMS Server
Enter ping <IP Address
of TMS Client PC>
TMS Client PC
replies to ping
Check network
cabling and
settings
TMS Server to
Projectors
Open command
prompt on TMS Server
Enter ping <IP Address
of Projector>
Projector replies to
ping
Check network
cabling and
settings
Check TMS Server
teaming
configuration
Open Task Manager
check that the
Application network
team is running at 4Gb
There is a team
connection and it is
running at 4Gb
Contact Sony
Engineer
UPS Tests
Procedure
Expected Result
If Test Fails
Test
Completed
Will the UPS
shutdown the system
if there is a power
cut?
Make sure the UPS is
fully charged and on
load protected mode.
Then disconnect the
power supply to the
UPS.
UPS will begin to
bleep and a
notification will
appear on the TMS
and CineWatch
Servers. After 20
minutes the TMS
and CineWatch
Servers will be
shutdown.
Check network
connection from
UPS to switch.
Ping UPS.
Configure the
Netwatch
software on the
TMS and
CineWatch
Servers.