![Sony Super HAD CCD SSC-DC132P Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/sony/super-had-ccd-ssc-dc132p/super-had-ccd-ssc-dc132p_service-manual_418350013.webp)
1-5
SSC-DC132P/134/134P/138P
F
H
SSC-DC138P
1
2
SSC-DC134
SSC-DC134P
VIDEO OUT
GND
SEE INSTRUCTION MANUAL
AC 24V
2
1
IRIS LEVEL
L
H
V PHASE
OFF
OFF
BLC
CCD-IRIS
2
1
3
G
VIDEO OUT
SEE INSTRUCTION MANUAL
DC 12V
IRIS LEVEL
L
H
OFF
OFF
BLC
CCD-IRIS
1
2
1
2
3
SSC-DC132P
VIDEO OUT
SEE INSTRUCTION MANUAL
IRIS LEVEL
L
H
V PHASE
OFF
OFF
BLC
CCD-IRIS
Connections
Connecting the SSC-DC134/DC134P
F
1
Connect the power lines to the camera.
2
Connect the 75-ohm coaxial cable to the video monitor.
3
Connect the wall outlet transformer.
Notes
• When using a transformer without a ground lead (two-lead type),
connect the output of the transformer to the AC 24V 1 and 2 terminals
of the camera.
• When using a transformer with a ground lead (three-lead type),
connect the ground lead to the GND terminal and the other two leads
to the AC 24V 1 and 2 terminals.
• To prevent a short circuit, do not let the exposed transformer leads
brush against conductive material when connecting to the AC 24V
terminals.
Connecting the SSC-DC132P
G
1
Connect the power lines to the camera.
2
Connect the 75-ohm coaxial cable to the video monitor.
3
Connect to the power supply.
1
+ 12V
2
GND (Ground)
Note
To prevent short circuits, do not let the exposed ends of the mains lead
wires touch each other when connecting to the mains lead terminals.
Connecting the SSC-DC138P
H
1
Connect the 75-ohm coaxial cable to the video monitor.
2
Connect the main lead.