SEL2470GM (FE 2.8 / 24-70 GM) (FE 24-70mm F2.8 GM)
4-2
Note 1:
Personal computer
(The SeusEX must be installed in the PC.)
OS:
Windows Vista / 7
RAM:
256 MB or more recommended (Windows 7)
1 GB or more recommended (Windows Vista)
USB port: USB 2.0 recommended (also compatible with 1.1)
Two connectors are required.
Run time: .NET Framework 2.0
(.NET Framework 2.0 is installed at lens adjustment program installation, if it is not installed.)
Note 2:
Attach the chart to the 1000 mm collimator as shown in Fig. 4-1-2.
Align the marks
1000 mm collimator
Chart
Fig.
4-1-2
(1) Setting of Equipments
Set the equipments and the lens to be tested as shown below.
4-1-3. Preparations for Equipments
Tripod
(optional)
AC
To tripod screw
USB cable
(1-829-868-41)
HASP key
To USB connector
Lens to
be tested
Camera
(ILCE-5000)
To USB connector
Lens to be tested
Lens to be tested
Personal computer
(The SeusEX must be installed in the PC.)
Windows Vista / 7
256 MB or more recommended (Windows 7)
1 GB or more recommended (Windows Vista)
USB 2.0 recommended (also compatible with 1.1)
Two connectors are required.
.NET Framework 2.0
(.NET Framework 2.0 is installed at lens adjustment
program installation, if it is not installed.)
OS:
RAM:
USB port:
Run time:
Within 10 mm
・
In the case of fixed focal lens
・
In the case of zoom lens
Within 10 mm
Flange back
adjustment jig
(J-6082-563-A)
FB Adjustment chart
or
Siemens star chart
(J-6080-875-A)
AC adaptor
(AC-PW20)
(1-487-963-12:EXCEPT US, CND)
(1-487-963-22:US, CND)
Flange back
adjustment jig
Flange back
adjustment jig
Fig. 4-1-3