Attention-when the product is installed in Rack:

1.  Prevention against overloading of branch circuit

  When this product is installed in a rack and is 

supplied power from an outlet on the rack, please 
make sure that the rack does not overload the supply 
circuit.

2.  Providing protective earth

  When this product is installed in a rack and is 

supplied power from an outlet on the rack, please 
confirm that the outlet is provided with a suitable 
protective earth connection.

3.  Internal air ambient temperature of the rack

  When this product is installed in a rack, please make 

sure that the internal air ambient temperature of the 
rack is within the specified limit of this product.

4.  Prevention against achieving hazardous 

condition due to uneven mechanical loading

  When this product is installed in a rack, please 

make sure that the rack does not achieve hazardous 
condition due to uneven mechanical loading.

5.  Install the equipment while taking the operating 

temperature of the equipment into consideration

  For the operating temperature of the equipment, refer 

to the specifications of the Operation Manual.

6.  When performing the installation, keep the 

following space away from walls in order to 
obtain proper exhaust and radiation of heat.

  Right, Left: 4 cm (1.6 inches) or more
  Rear: 

10 cm (3.9 inches) or more

設置時には,通気やサービス性を考慮して設置スペース
を確保してください。

.

  ファンの排気部 ( リアパネル面,右側面後ろ側,トッ

プパネル後ろ側 )  や通気孔(フロントパネル面,左側
面フロント側)をふさがない。

.

  通気のために,セット周辺に空間をあける。

.

  作業エリアを確保するため,セットの左側面および右

側面は 4 cm 以上,セット後方は 40 cm 以上の空間を
あける。

机上などの平面に設置する場合は,左側面および右側面
は 4 cm 以上の空間をそれぞれ確保してください。ただ
し,セット上部はサービス性を考慮し 40 cm 以上の空
間を確保することを推奨します。

When installing, the installation space must be secured 
in consideration of the ventilation and service operation.

.

  Do not block the fan exhaust areas (rear panel and 

rear part of the right side panel and rear part of the top 
panel) and vents (front panel, front part of the left side 
panel) with objects.

.

  Leave a space around the unit for ventilation.

.

  Secure working spaces (at least 4 centimeters from 

the left panel and right panel and at least 40 centime-
ters from the rear panel of the unit).

When the unit is installed on the desk or the like, leave at 
least 4 centimeters of space in the left and right sides.
Leaving 40 centimeters or more of space above the unit 
is recommended for service operation.

Содержание PWS-110RX1

Страница 1: ...NETWORK RX STATION PWS 110RX1 OPTIONAL POWER SUPPLY PWSK 101 INSTALLATION MANUAL 1st Edition Serial No 120001 and Higher PWS 110RX1 SY ...

Страница 2: ...r Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVERTISSEMENT Ce manual est destiné uniquement aux personnes compétentes en charge de l entretien Afin de réduire les risques de décharge électrique d incendie ou de blessure n effectuer que les réparations indiquées dans le mode d emploi à moins d...

Страница 3: ...of the equipment refer to the specifications of the Operation Manual 6 When performing the installation keep the following space away from walls in order to obtain proper exhaust and radiation of heat Right Left 4 cm 1 6 inches or more Rear 10 cm 3 9 inches or more 設置時には 通気やサービス性を考慮して設置スペース を確保してください ファンの排気部 リアパネル面 右側面後ろ側 トッ プパネル後ろ側 や通気孔 フロントパネル面 左側 面フロント側 をふさがない 通気のために セット周辺に空間をあける 作業エリアを確保するため セ...

Страница 4: ......

Страница 5: ...wer Supply 1 4 E 1 4 1 Power Supply Specifications 1 4 E 1 4 2 Recommended Power Cord 1 4 E 1 5 Installing an Optional Power Unit 1 5 E 1 6 Rack Mounting 1 6 E 1 6 1 Parts Required 1 7 E 1 6 2 Removing the Front Panel 1 8 E 1 6 3 Mounting to Rack M5 Screw Holes 1 8 E 1 6 4 Mounting to Rack Square Holes 1 8 E 1 6 5 Installing the Front Panel 1 10 E 1 7 Connector Input Output Signals 1 11 E 1 8 Conn...

Страница 6: ...it Service Manual Available on request This manual describes service overview error messages periodic maintenance and inspection replacement of main parts and so on of the unit to provide information required for block level service Installation manual for RMM 10 Supplied with RMM 10 This is necessary to install the unit to a 19 inch equipment rack Trademarks Trademarks and registered trademarks d...

Страница 7: ... to the Installation Manual for RMM 10 This process is not necessary if you don t mount this unit into a rack 1 6 4 Mounting to Rack Square Holes This process is not necessary if you don t mount this unit into a rack 1 6 5 Installing the Front Panel 1 7 Connector Input Output Signals 1 8 Connectors and Cables Check the operation of the unit depending on the configuration of the system 1 6 1 Part R...

Страница 8: ...ted installation places Places exposed to direct sunlight or intense light Places near a heat source Dusty places or places subject to constant vibration Places in strong magnetic field Places subject to much electrical noise Places where electrostatic noise is likely to be generated Places where specified installation space cannot be provided Refer to 1 3 2 Installation Space Sealed places Maximu...

Страница 9: ...rs or more of space above the unit is recommended for service operation 482 43 6 7 22 500 162 5 Unit mm 115 5 115 5 440 15 3 Mass of this unit not including option approx 9 8 kg Moreover an air flow that is effective in cooling the unit is essential If the ventilation is not enough the unit may be damaged because of an increase of the internal tempera ture n This unit is air cooled by the fans The...

Страница 10: ... of the AC power supply on the supply side may trip or the unit may malfunction 1 4 2 Recommended Power Cord This unit does not come with a power cord To get a power cord please contact your local Sony Sales Office Service Center w Use the approved Power Cord 3 core mains lead Appli ance Connector Plug with earthing contacts that con forms to the safety regulations of each country if appli cable U...

Страница 11: ...he rear panel power Rear panel power assembly Rear panel power Blank panel power B3 8 B3 8 3 Insert the power unit n Make sure that the power unit has been locked after the insertion The power unit cannot be drawn out by pulling the handle without pulling up the lever Power unit 4 Align the hole to the boss attach the rear panel power and then tighten the four screws B3 x 8 n First tighten the scr...

Страница 12: ...your back Use the specified rack mount kit The use of other kit of low strength may drop the unit and cause the risk of injury Fix the rack to the floor When the rack turns over with the heaviness of the unit it causes the death and the serious injury After rack mounting fix the unit to the rack securely If the screws of rack angle are not fastened the unit may slip down and dropped from the rack ...

Страница 13: ...ack bracket 2 pcs Rack mount adaptor right 1 pc Including screw B4 x 6 7 682 560 09 2 pcs Rack mount adaptor left 1 pc Including screw B4 x 6 7 682 560 09 2 pcs Rack bracket attachment screw B4 x 6 7 682 560 09 6 pcs Adaptor attachment screw B4 x 10 7 682 560 10 6 pcs Screws for Rack Mount Screw for rack mount B5 x 12 7 682 576 04 4 pcs t These parts are supplied with this unit Parts for square ho...

Страница 14: ...s at the tightening torque below Tightening torque 120 x 10 _2 N m 12 2 kgf cm 1 Attach the rack brackets in the side panels of the unit with the specified six screws B4 x 6 Rack bracket Rack bracket B4 6 B4 6 2 Remove the release paper of the plate nut M5 and stick the plate nut to the front of the adaptor n Align the adaptor with the plate nut M5 at the top edges and at the lateral edges Make su...

Страница 15: ...ont Positioning plate Bosses Bosses Square Holes B4 10 B4 10 Positioning plate Viewed from inside the rack angle Rear 5 Tighten the length adjustment screws B4 x 6 two screws for each bracket which are loosened in step 3 6 Align the bent section of the each rack bracket on the side panels of the unit to the rail and then slide the unit backward t Each rack bracket covers the rails as shown in the ...

Страница 16: ... the rail or trouble attaching the front panel to the unit adjust the position of positioning plate Positioning plate 1 6 5 Installing the Front Panel Attach the front panel to the main unit and tighten the two anti drop screws Anti drop screw Front panel Anti drop screw ...

Страница 17: ...tive 3 SDI1 to 4 BNC 4 Impedance 75 Z 1 Voltage 0 8 V p p HD SMPTE ST 292 1 compatible SD SMPTE ST 259 compatible 4 USB Super Speed USB USB 3 0 Type A 4 Among four right lower connector supports to the power supply 900 mA Others do not support to the power supply 5 LAN1 2 RJ 45 8 pin 2 1000BASE T 100BASE TX 6 HDMI Type A 1 HDMI Ver 1 4a 1920 x 1200 maximum resolution 60 Hz 7 DisplayPort This conne...

Страница 18: ...t No Remarks REF IN BNC 75 Z MALE 1 569 370 12 _ SDI 1 to 4 BNC 75 Z MALE 1 569 370 12 _ HDMI HDMI type A The HDMI cable use a product made in Sony Recommended HIGH SPEED HDMI cable DLC HE20XF 2 m _ _ USB Use a cable for super speed USB _ _ SYSTEM BNC 75 Ω MALE 1 569 370 12 _ LAN1 2 Network cable STP cable is recommended _ Commercially available STP Shielded Twisted Pair ...

Страница 19: ...Onboard Switches 2 1 1 Settings of Onboard Switch n Be sure not to change the default settings of switches on the board Board Ref No Factory Setting Knob position MB 1204 S800 1 2 O N 3 4 5 6 7 8 S2201 CFG 1 2 O N 3 4 HPR 48 S4002 1 2 O N 3 4 5 6 7 8 ...

Страница 20: ......

Страница 21: ......

Страница 22: ...Sony Corporation PWS 110RX1 SY J E 4 596 995 01 Printed in Japan 2016 8 08 2016 ...

Отзывы: