23
HCD-CZ1/NAS-CZ1
SECTION 4
TEST MODE
FORCED RESET
*
The cold reset clears all data including preset data stored in
the RAM to initial conditions. Execute this mode when
returning the set to the customer.
Procedure:
1. Press the
I/
1
button to turn the power on.
2. Press three buttons of
I/
1
,
x
and
[5]
simultaneously.
3. The message “COLD RESET” is displayed on the fluorescent
indicator tube momentarily after “See you!” is displayed, then
becomes standby states.
AMP TEST MODE
Procedure:
1. Press the
I/
1
button to turn the power on
2. Press three buttons of
VOL –
,
N
and
[2]
simultaneously.
3. In this mode, change the display as “MIN”
y
“21”
y
“MAX” by pressing the
VOL –
/
VOL +
buttons.
4. To release this mode, press the
I/
1
button to execute the cold
reset and becomes standby status.
DISPLAY CHECK MODE
This mode is used to check the fluorescent indicator tube and LEDs.
Procedure:
1. Press the
I/
1
button to turn the power on.
2. Press three buttons of
VOL –
,
N
and
[3]
simultaneously.
3. When this mode is activated, the fluorescent indicator tube
and LEDs are all turned on.
4. In this mode, change the display as follows by pressing the
[NETWORK]
button.
All on
t
FL all off
t
FL pattern 1
t
FL pattern 2
t
LED
all off
t
[1]
LED on
t
[2]
LED on
t
[3]
LED on
t
[4]
LED on
t
[5]
LED on
t
I/
1
LED on
t
[NETWORK]
LED on
t
All on
t
...
5. To release this mode. press the
I/
1
button to execute the cold
reset and becomes standby status.
KEY CHECK MODE
Procedure:
1. Press the
I/
1
button to turn the power on.
2. Press three buttons of
VOL –
,
N
and
[4]
simultaneously.
3. If this mode is activated, “KEY-00/12” is displayed on the
fluorescent indicator tube.
4. In this mode, each time any key is pressed, it increment the
number of display until “KEY-12/12”
5. To release this mode, press three buttons of
VOL –
,
N
and
CHANGE-OVER THE AM TUNING INTERVAL
(EXCEPT AEP, UK models)
The AM tuning interval can be changed over 9kHz or 10kHz
button to turn the power on.
button again to turn the power off (standby).
button, press the
I/
1
button.
5. It turns power on and display “STEP 9kHz” or “STEP 10kHz”,
and thus the tuning interval is changed over.
VERSION CHECK MODE
*
This mode is used to check the version of model, destination
and software.
Procedure:
1. Press the
I/
1
button to turn the power on.
2. Press three buttons of
VOL +
,
[NETWORK]
and
[1]
simultaneously.
3. when this mode is activated, model and destination is displayed
on the fluorescent indicator tube.
4. In this mode, change the version display as model/destination
t
CD-STR
t
Ethernet system
t
model/destination
t
...
5. To release this mode, press the
I/
1
button to execute the cold
reset and becomes standby status.
CD ERROR HISTORY DISPLAY MODE
*
This mode can be used for error code display of CD section.
Procedure:
1. Press the
I/
1
button to turn the power on.
2. Press the
[FUNCTION]
button to select “CD”.
3. Press three buttons of
VOL +
,
N
and
[3]
simultaneously.
4. When this mode is activated, it displays as follows.
Error count display:
Em 0Ed##
Em0
: Not used
Ed##
: Error count of BD section
5. In this mode, change the display as error count
y
“MO”
display (not used)
y
error detail by pressing the
[ALBUM -]
/
[ALBUM +]
keys on remote commander (RM-ANP002).
6. In the error detail display mode, change the error number and
that error detail by pressing the
.
or
>
keys on remote
commander (RM-ANP002).
Error detail display:
0***********
*
: Hexadecimal number (refer to following table for detail)
7. To release this mode, press the
I/
1
button to turn the power
off or press the
[FUNCTION]
button to change the function.