1-22
MVS-8000X/7000X
D4101 to D4103 (D-2) : DB0 ETHER
Ethernet communication status indication for maintenance.
.
D4101 (100)
: Lights when linked by 100base-
TX.
.
D4102 (1000)
: Lights when linked by
1000base-T.
.
D4103 (LINK/ACT) : Lights when linked, and blinks
when communicating.
< Switch >
S401 (F-1) : CA RESET
Reset the board.
S402 (F-1) : SWER RESET
Reset the all system, and restart.
S501 (M-1) : MON
Start up in monitor mode when press S401, S402 or power
on while pressing this switch.
S901/S904 (E-1, F-1) : SETTING1, SETTING2
Sets the software mode.
Default setting when shipped from the factory is all OFF.
S902 (G-1) : GROUP ID
Sets the GROUP ID for connecting LAN. Do not change
the setting.
In the default settings when shipped from the factory, bit 1
is set to ON and others are set to OFF.
S903 (G-1) : UNIT ID
Sets the UNIT ID for connecting LAN. Do not change the
setting.
In the default settings when shipped from the factory, bit 1
is set to ON and others are set to OFF.
S2201 (E-7) : NEP1 RESET
Reset the NEP1.
S2202 (F-6) : NEP1 SET
Sets the start-up mode of NEP1.
In the default settings when shipped from the factory, bit 8
is set to ON and others are set to OFF.
S2301 (H-7) : NEP2 RESET
Reset the NEP2.
S2302 (J-7) : NEP2 SET
Sets the start-up mode of NEP2.
In the default settings when shipped from the factory, bit 8
is set to ON and others are set to OFF.
< LED on the CPU-DP Module >
D1 (L-6) : 3.3 V
Power supply status indication.
Lights when
+
3.3 V power is supplied to the regulator on
CPU-DP module.
D2 (L-6) : 2.5 V
Power supply status indication.
Lights when
+
2.5 V power is supplied normally.
D3 (L-6) : 1.8 V_DDR
Power supply status indication.
Lights when
+
1.8 V power is supplied normally to the
DDR2 on CPU-DP module.
D4 (L-6) : 1.2 V
Power supply status indication.
Lights when
+
1.2 V power is supplied normally.
D5 (L-6) : 1.1 V
Power supply status indication.
Lights when
+
1.1 V power is supplied normally.
D6 (R-4) : CD
Lights when the connector on CPU-DP module connected
to the base board normally.
D7 (N-2) : RUN
Lights when complete the boot process normally of CPU-
DP module.
D8 to D11 (N-2) : STATUS LED1 to 4
Internal status indication of CPU-DP module.
Controlled by software.
D12 (N-2) : GbE1
Lights when linked Ethernet 1 on CPU-DP module.
On this board, corresponds to Network C connection.