MHC-V41D
15
2-7. CDM BLOCK
8
Remove the CDM block
in the direction of the arrow.
3
flexible flat cable (24P) (CN302)
(from optical pick-up block)
(See Fig. F)
6
two screws
(BVTP3
u
8)
front side
DC fan cable
rear side
2
flexible flat cable (5P)
(CN303) (from MS-476 board)
(See Fig. F)
1
OP cable
connector
(CN402)
(See Fig. F)
'&IDQFDEOHVHWWLQJ
:LUHVHWWLQJ
MOTHER board
right side
coating clip
7
two screws
(BVTP3
u
8)
groove
Note 2:
The DC fan cable must not touch
the heat sink.
heat sink
hole
boss
boss
hole
9
CDM block
Note
1:
When installing the CDM block,
align the two bosses and two holes.
–
5LJKWYLHZ
–
front side
rear side
flexible flat cable (5P)
(from MS-476 board)
CN303
MOTHER board
)LJ)!
terminal side
CN302
CN402
terminal side
flexible flat cable (24P)
(from optical pick-up block)
OP cable
heat sink
top side
4
Remove the DC fan cable
from the coating clip.
5
Remove the DC fan cable
from the groove.
–
&'0EORFNERWWRPYLHZ
–