1-2. Display in Destination Setting Mode
(Displayed characters/values in the following
fi
gure are example)
Destination code
12 digits
OP0
OP1
OP2
OP3
OP4
OP5
1-3. Entering the Destination Code
• Method of operation by main unit
1. Rotate the control dial, and select the alphanumeric character
of “0 to F”.
2. The digit advances by pressing the [PUSH ENTER/VOICE] or
[
> M
SEEK+] button.
The digit returns by pressing the [ MODE] or [SEEK–
m
.
] button.
3. The setting is completed by pressing the [PUSH ENTER/
VOICE] button, then the display turns off, the initialization
operation is done, and the display returns to the clock display.
• Method of operation by remote commander
(Except AEP and UK models only)
Note:
The model to which the remote commander is not attached can
also be operated by using the remote commander.
1. Press the [
V
] or [
v
] button, and select the alphanumeric char-
acter of “0 to F”.
2. The digit advances by pressing the [
b
] button.
The digit returns by pressing the [
B
] button.
3. The setting is completed by pressing the [ENTER] button, then
the display turns off, the initialization operation is done, and
the display returns to the clock display.
1-4. Destination Code
Destination
OP5
OP4
OP3
OP2
OP1
OP0
US, Canadian
5
2
8
2
A
2
AEP, UK
1
2
8
0
A
1
Russian
1
3
8
0
A
7
E, Australian
1
6
B
0
A
0
Saudi Arabia
1
6
A
0
A
4
2. Con
fi
rmation After Destination Setting
Execute the following operation after completing the destination
setting, and con
fi
rm a correct destination was set.
Destination setting checking method:
1. In the state of source off (the clock is displayed on the liquid
crystal display), enter the test mode by pressing the buttons in
order of the [ 4]
t
[MIC 5]
t
[PAUSE 6] (press only the
[PAUSE 6] button for two seconds).
(Displayed characters/values in the following
fi
gure are ex-
ample)
Clock diaplay
2. In the state in which the software main version is displayed
on the liquid crystal display (refer to following
fi
gure), enter
the destination setting value display mode by pressing the [
SCRL DSPL] button twice.
(Displayed characters/values in the following
fi
gure are ex-
ample)
Software main version
3. Con
fi
rm the alphanumeric character of 12 digits in liquid crys-
tal display is a value correctly input.
(Displayed characters/values in the following
fi
gure are ex-
ample)
Destination code
12 digits
OP0
OP1
OP2
OP3
OP4
OP5
4. The resetting operation is executed by pressing the [
OFF
SRC] button for 1 second after the con
fi
rming ends, and the
unit returns to the normal condition.