37
MDS-SE9
6. Press the
MD
.
or
MD
>
button so that the reading of
the laser power meter becomes the specified value, press the
[ENTER/START]
button to save it.
Note:
Do not perform the emission with 8.65mW more than 15 seconds
continuously.
Specified Value:
7. Then,press the
MD
.
or
MD
>
button to display
“LDPWR CHECK” (C13).
8. Press the
[ENTER/START]
button once to display “L 0.93mW$
”. Check that the reading of the laser power meter matches
with the specified value.
Specified Value:
9. Press the
[ENTER/START]
button once more to display “L
8.65mW$
”. Check that the reading the laser power meter
and digital voltmeter satisfy the specified value.
Note down the digital voltmeter reading value.
Specified Value:
Laser power meter reading :
8.10 to 8.70mW (KMS-262A)
8.40 to 8.90mW (KMS-262E)
Digital voltmeter reading
: Value on the optical pick-up label ±10%
10. Press the
[MODE]
button to display “LDPWR CHECK”
(C13) and stop the laser emission.
(The
[MODE]
button is effective at all times to stop the laser
emission)
11. Press the
MD
.
or
MD
>
button to display “Iop Write”
(C05).
12. Press the
[ENTER/START]
button. When the display becomes
Ref=@@@.@ (@ is an arbitrary number), press the
[ENTER/
START]
button to display “Measu=@@@.@” (@ is an arbitrary
number).
13. The numbers which can be changed will blink. Input the Iop
value noted down at step 9.
To select the number : Press the
MD
.
or
MD
>
button.
To select the digit
: Press the
[TAPE REC]
button.
14. When the
[ENTER/START]
button is pressed, “Complete!” will be
displayed momentarily. The value will be recorded in the non-
volatile memory and the display will become “Iop Write” (C05).
Note:
After step 9, each time the
[ENTER/START]
button is pressed, the
display will be switched to “L 0.73mW$
”, “L 7.70mW$
”
“L WP
$
” Nothing needs to be performed here.
11. Iop NV Save
Write the reference values in the nonvolatile memory to perform
“Iop compare”. As this involves rewriting the reference values, do
not perform this procedure except when adjusting the laser power
during replacement of the optical pick-up and when replacing the
IC102. Otherwise the optical pick-up check may deteriorate.
Note:
Perform this function with the optical pick-up set at room temperature.
Procedure:
1. Press the
MD
.
or
MD
>
button to display “Iop NV Save”
(C06).
2. Press the
[ENTER/START]
button and display “Iop [stop]”.
12. Traverse Adjustment
Connection:
Procedure:
1. Connect an oscilloscope to CN105 pin
4
(TE) and CN105 pin
6
(VC) on the BD board.
2. Load a disc (any available on the market). (Refer to Note 1)
3. Press the
TAPE
M
button to move the optical pick-up outside
the pit.
4. Press the
MD
.
or
MD
>
button to display “EF MO
ADJUST” (C07).
5. Press the
[ENTER/START]
button to display “EFB =
MO-R”.
(Laser power READ power/Focus servo ON/tracking servo OFF/
spindle (S) servo ON)
6. Press the
MD
.
or
MD
>
button so that the waveform of
the oscilloscope becomes the specified value.
(When the
MD
.
or
MD
>
button is pressed, the
of
“EFB=
” changes and the waveform changes) In this adjustment,
waveform varies at intervals of approx. 2%. Adjust the waveform
so that the specified value is satisfied as much as possible.
(Read power traverse adjustment)
Traverse Waveform
Note 1:
Data will be erased during MO reading if a recorded disc is
used in this adjustment.
Note 2:
If the traverse waveform is not clear, connect the oscilloscope
as shown in the following figure so that it can be seen more
clearly.
KMS262E
20101
B0576
lop=57.6 mA in this case
lop (mA) = Digital voltmeter reading (mV)/1 (
Ω
)
(Optical pick-up label)
For details of the method for
checking this value, refer to
“8. Recording and Displaying
the Iop Information”
+
–
oscilloscope
(DC range)
V: 0.1 V/div
H: 10 ms/div
BD board
CN105 pin
4
(TE)
CN105 pin
6
(VC)
A
B
VC
Specification A = B
3.
After the display changes to “Iop =
save?”, press the
[ENTER/
START]
button.
4.
After “Complete!” is displayed momentarily, the display
changes to “Iop 8.4 mW”.
5.
After the display changes to “Iop=
save?”, press the
[ENTER/
START]
button.
6.
When “Complete!” is displayed, it means that Iop NV saving
has been completed.
+
–
oscilloscope
(DC range)
10 pF
330 k
Ω
CN105 pin
4
(TE)
CN105 pin
6
(VC)
BD board
7. Press the
[ENTER/START]
button and save the result of
adjustment to the non-volatile memory (“EFB =
SAVE”
will be displayed for a moment. Then “EFB =
MO-W” will
be displayed).
KMS-262A
8.2 to 8.6mW
KMS-262E
8.5 to 8.8mW
KMS-262A
0.84 to 0.92mW
KMS-262E
0.90 to 0.96mW