4-11 (E)
MAV-555
4-5-2. D/A Video Level Adjustment
m
Check the following setup menus before starting adjust-
ment.
.
Check the NTSC/PAL setup. (Refer to menu No. 010 of
Section 1-9-2 of the MAV-555 Installation Manual.)
.
Check the network setup. (Refer to menu No. 220 of
Section 1-9-6 of the MAV-555 Installation Manual.)
Connection
Setting
1.
Open “782-INT VD SG R1” of the setup menu.
n
For details on how to use the setup menu, refer to the
Operation Manual.
2.
Press the VIDEO/MENU knob once.
3.
Turn the VIDEO/MENU knob and select “CB100”
(100% color-bar signal).
4.
Press the SET button.
5.
Set “703-OUT SETUP P1” or “704-OUT SETUP P2”
to “off” on the setup menu in accordance with the port
that the BKMA-512 is connected to. (Refer to Section
1-9-5 of the MAV-555 Installation Manual.)
n
The setting is not required in case of the 625-mode
(PAL).
6.
Turn off the main power and back on. Restart the
MAV-555.
n
To restart the MAV-555 quickly, execute “027-FAST
REBOOT” of the setup menu.
7.
Press the R1 button on the PORT SELECT block of
the meter panel.
(Set so that the internal SG is output to the R1 port.)
8.
Press the COMPOSITE button of the VIDEO INPUT
SELECT block of the meter panel for at least three
seconds. (The internal SG starts, and the COMPOSITE
button and the SDI button are turned on.)
9.
Press either the P1 or the P2 button of the PORT
SELECT block of the meter panel in accordance with
the port to which the BKMA-512 is connected.
10. Press the CONTROL button of the VIDEO PROCESS
block on the meter panel several times, and enter the
LOCAL mode.
11. Set all buttons of VIDEO, CHROMA, SETUP, and
CHROMA PHASE on the meter panel to “PRESET”.
4-5. DA-136 Board Adjustment
VIDEO OUT
*
P1-A
or
P2-A
ETHER
Waveform monitor
or an oscilloscope
Ethernet
PC
MAV-555
+
BKMA-512
*
: Connect to the VIDEO OUT P1-A or the VIDEO OUT P2-A in
accordance with the port to which the BKMA-512 is connected.
782-INT VD SG R1
off
782-INT VD SG R1
CB100