1-4. Upgrading the Software (excluding PU-109 board)
This section describes how to upgrade the software of each board (FM-68, TM-40, DM-120, EM-1) using
the software download tool (GCD loader).
Connection
Connect the Ethernet cable to the Ether terminal of the rear panel.
Table of required files (example)
c:MAV-555\GCDloader.exe :
Software download tool
c:MAV-555\Fm\FM_V101.hex :
Software module of FM-68 board (Ver. 1.01)
c:MAV-555\Fm\FM_V102.hex :
Software module of FM-68 board (Ver. 1.02)
c:MAV-555\Tm\TM_V101.hex :
Software module of TM-40 board (Ver. 1.01)
c:MAV-555\Tm\TM_V102.hex :
Software module of TM-40 board (Ver. 1.02)
c:MAV-555Dm\DM_V101.hex :
Software module of DM-120 board (Ver. 1.01)
c:MAV-555\Dm\DM_V102.hex :
Software module of DM-120 board (Ver. 1.02)
c:MAV-555\Em\EM_V101.hex :
Software module of EM-1 board (Ver. 1.01)
c:MAV-555\Em\EM_V102.hex :
Software module of EM-1 board (Ver. 1.02)
Preparation
1.
Confirm that [019-SYSTEM OPERATE CONFIGURATION] of the set-up menu is set to [PANEL].
If not, change the setting and restart the MAV-555.
2.
Set all ports to the unload.
3.
Set the IP address and the sub-net mask of the MAV-555 to the factory settings.
m
.
The IP address and sub-net mask can be confirmed in set-up menu No. 220.
.
The factory settings are as follows:
IP address :
192.168.0.1
Sub-net mask : 255.255.255.0
4.
Set the IP address and the sub-net mask of the personal computer as follows:
IP address: 192.168.0.2
Sub-net mask: 255.255.255.0
5.
Start up the personal computer.
6.
Wait for the MS-DOS prompt (or command prompt) to appear.
7.
Input [ping 192.168.0.1].
8.
Confirm that the reply is returned normally.
9.
If the reply is not returned normally, input [arp -d 192.168.0.1] and perform from step 7 again.
(When downloading to several MAV-555s continuously, the information of the ARP table may
remain.)