2-4. FOCUS ADJUSTMENT
Confi rm neck assembly Z axis position
1. Input a dot signal.
2. Set Video Mode to STANDARD.
3. Input a HD monoscope signal.
4. Confi rm center focus with focus VR.
NECK ASSEMBLY
NOTE
: Just position is the adjustment
position from the center location
indicated.
FOCUS
Screen (G2)
DOT SHAPE:
NOTE:
The Neck Assembly tilt
can effect dot shape.
NOTE
: Changing neck assembly position will affect corner convergence.
2-4.1. DYNAMIC FOCUS/DYNAMIC QUADRA-POLE DATA
Normally, no adjustments are necessary for these systems. If for some reason the data is lost, use the initial data.