— 35 —
KP-46WT510
2-15.AUTO REGISTRATION ERROR CODES
If an error code is displayed after the set has been correctly adjusted, check the following items: position, tilt and sizing. If any of these adjustments
are off, even slightly, the auto-registration pattern will not hit the four sensors properly. This occurs when the internal generator patterns are being
fl ashed on the screen for the sensors to read. Therefore, auto registration (called auto convergence) cannot operate properly, causing an error code to
be displayed. In order for this function to operate properly correct position, tilt, and size must be adjusted properly.
ERROR CODE LIST
ERROR
CODE
DESCRIPTION
NOTE
00
No Error
10
Sensor 0 low output
Check sensor 0, connection/wiring, circuit, and pattern position
(are patterns hitting sensor?) adjust 66 VUP, 70 HMID if necessary.
11
Sensor 1 low output
Check sensor 1, connection/wiring, circuit, and pattern position
(are patterns hitting sensor?) adjust 69 HLE, 67 VMID if necessary.
12
Sensor 2 low output
Check sensor 2, connection/wiring, circuit, and pattern position
(are patterns hitting sensor?) adjust 71 HRIV, 67 VMID if necessary.
13
Sensor 3 low output
Check sensor 3, connection/wiring, circuit, and pattern position
(are patterns hitting sensor?) adjust 68 VLOW, 70 HMID if necessary.
20
Sensor 0 high output
Check sensor 0 and circuit.
21
Sensor 1 high output
Check sensor 1 and circuit.
22
Sensor 2 high output
Check sensor 2 and circuit.
23
Sensor 3 high output
Check sensor 3 and circuit.
30
V CENT or SKEW adjustment loop overflow
Check 67 VMID data and check registration condition.
31
H CENT or SKEW adjustment loop overflow
Check 70 HMID data and check registration condition.
32
H LIN or SIZE adjustment loop overflow
Check 69 HLE and 71 HRIV data and check registration condition.
40
V CENT regi data overflow
Check 67 VMID data and confirm V CENT data (all modes) is not near 511.
41
H CENT regi data overflow
Check 70 HMID data and confirm H CENT data (all modes) is not near 511.
42
V SKEW regi data overflow
Check 67 VMID data and confirm V SKEW data (all modes) is not near 511.
43
H SKEW regi data overflow
Check 70 HMID data and confirm H SKEW data (all modes) is not near 511.
44
H LIN regi data overflow
Check 69 HLE and 71 HRIV data and confirm H CENT data (all modes)
is not near 511.
45
H SIZE regi data overflow
Check 69 HLE and 71 HRIV data and confirm H CENT data (all modes)
is not near 511.
50
V CENT regi data overdrow
Check 67 VMID data and confirm V CENT data (all modes) is not near -512.
51
H CENT regi data overdrow
Check 70 HMID data and confirm H CENT data (all modes) is not near -512.
52
V SKEW regi data overdrow
Check 67 VMID data and confirm V SKEW data (all modes) is not near -512.
53
H SKEW regi data overdrow
Check 70 HMID data and confirm H SKEW data (all modes) is not near -512.
54
H LIN regi data overdrow
Check 69 HLE and 71 HRIV data and confirm H
LIN
data (all modes)
is not near -512.
55
H SIZE regi data overdrow
Check 69 HLE and 71 HRIV data and confirm
H SIZE
data (all modes)
is not near -512.
60
CENT/SKEW calibration loop overflow
Check 70 HMID and 67 VMID data and check registration condition.
61
SIZE/LIN calibration loop overflow
Check 69 HLE, 71 HRIV, 66 VUP, and 68 VLOW data and
check registration condition.
70
V CENT/SKEW ratio limit
Check sensors 1 and 2, connection/wiring, circuit, increase 65 RTLM.
71
H CENT/SKEW ratio limit
Check sensors 0 and 3, connection/wiring, circuit, increase 65 RTLM.
73
H SIZE/Lin ratio limit
Check sensors 1 and 2, connection/wiring, circuit, increase 65 RTLM.
80
SIZE Limit Error
Check that horizontal SIZE data is not near 64 SZLM.
Содержание KP-46WT510 - 46" 16:9 Hi-scan Projection Television
Страница 20: ... 20 KP 46WT510 ADJUSTABLE SERVICE DATA LISTS ...
Страница 21: ... 21 KP 46WT510 ADJUSTABLE SERVICE DATA LISTS ...
Страница 22: ... 22 KP 46WT510 ADJUSTABLE SERVICE DATA LISTS ...
Страница 23: ... 23 KP 46WT510 ADJUSTABLE SERVICE DATA LISTS ...
Страница 24: ... 24 KP 46WT510 ADJUSTABLE SERVICE DATA LISTS ...
Страница 25: ... 25 KP 46WT510 ADJUSTABLE SERVICE DATA LISTS ...
Страница 26: ... 26 KP 46WT510 ADJUSTABLE SERVICE DATA LISTS ...
Страница 27: ... 27 KP 46WT510 ADJUSTABLE SERVICE DATA LISTS ...
Страница 28: ... 28 KP 46WT510 ADJUSTABLE SERVICE DATA LISTS ...
Страница 29: ... 29 KP 46WT510 ADJUSTABLE SERVICE DATA LISTS ...