The units in this manual contain a self-diagnostic function. If an error occurs, the POWER/STANDBY will automatically begin to fl ash. The number of
times the LED fl ashes translates to a probable source of the problem. A defi nition of the POWER/STANDBY fl ash indicators is listed in the instruction
manual for the user’s knowledge and reference. If an error symptom is diffi cult to reproduced use the Remote Commander to display the record that is
stored at the internal NVM to specify the cause of the failure.
Diagnostic Test Indicators
When an error occurs, the POWER/STANDBY will fl ash a set number of times to indicate the possible cause of the problem. If there is more than
one error, the POWER/STANDBY will identify the fi rst of the problem areas. If the errors occur simultaneously, the one that corresponds to the fewest
fl ashes is identifi ed fi rst.
Results for all of the following diagnostic items are displayed on screen. (No error has occurred if the screen displays a “0”.)
Number of times
LED indicator
flashes Diagnosis
Item
Probable
Cause
1 Lamp
Error
Lamp not seated properly
(Note: The lamp LED will flash red when
this error occurs, not the Power LED)
2
OVP
10.5V is high on B Board
3
LowB Error
10.5V is low on B Board
4
Not Used in this model
5 HV
Detect
Ballast
is
not
working
6
Lamp Cover/ Lamp Position
The Lamp cover is not closed securely.
7
Temp Error
High Temperature or sensor connection
8 Audio
Error
DC
error
on
U
Board
9 Fan
Error
Fan
is
not
working
properly
DISPLAY OF POWER/STANDBY OR LAMP LED FLASH COUNT
TIMER
LAMP
POWER
TIMER
LAMP
POWER
Screen
Flashes red for all except Lamp error
Flashes red for Lamp error
- Example
Diagnosis
Number of times LED Flashes
3 times
Lamp Cover
6 times
LED ON : 0.3 sec
LED OFF : 0.3sec
LED OFF
3.0sec
LED OFF
3.0sec
LowB Error
- 4 Flash is not used for self-diagnosis