10
ICF-C112
SECTION 5
DIAGRAMS
THIS NOTE IS COMMON FOR PRINTED WIRING
BOARDS AND SCHEMATIC DIAGRAMS.
Common Note on Schematic Diagram:
• All capacitors are in µF unless otherwise noted. pF: µµF
50 WV or less are not indicated except for electrolytics
and tantalums.
• All resistors are in
Ω
and
1
/
4
W or less unless otherwise
specified.
•
f
: internal component.
•
C
: panel designation.
•
A
: B+ Line.
•
H
: adjustment for repair.
• Total current is measured with no-signal.
• Power voltage is dc 9V and fed with regulated dc power
supply from battery terminal.
• Voltage is dc with respect to ground under no-signal
(detuned) condition.
no mark : FM
(
) : AM
• Voltages are taken with a VOM (Input impedance 10 M
Ω
).
Voltage variations may be noted due to normal produc-
tion tolerances.
• Signal path.
F
: FM
f
: AM
Note: The components identified by mark
0
or dotted line
with mark
0
are critical for safety.
Replace only with part number specified.
Common Note on Printed Wiring Boards:
•
X
: parts extracted from the component side.
•
Y
: parts extracted from the conductor side.
•
f
: internal component.
•
: Pattern from the side which enables seeing.