24
When attaching an aberration correction lens
The aberration correction function is activated automatically.
Starting the camera with an aberration correction lens may require
more time than normal because of data loading at start-up.
The lens supplied with the HXC-FB80K/HXC-FB80S is an
aberration correction lens. Contact your Sony dealer or a Sony
service representative for information about other aberration
correction lenses.
Adjusting the flange back (flange focal length)
If the lens does not stay in focus properly as you zoom from
telephoto to wide angle, adjust the flange focal length (the distance
from the plane of the lens mounting flange to the imaging plane).
This adjustment is required once only after attaching or changing the
lens.
When carrying out the adjustment, use the supplied flange focal
length adjustment chart as the subject.
• If you use a subject with insufficient contrast, or move the camera or
subject during adjustment, this will cause an adjustment error.
• Place the subject (the flange focal length adjustment chart) so that it
appears at the center of the screen at the telephoto end. Arrange so that no
nearby object (no object closer to the camera than the chart) enters the
screen at the wide-angle end.
1
Set the iris to manual, and open the iris.
2
Position the supplied flange focal length adjustment chart
approximately 3 m (10 ft) away from the camera, and
arrange the lighting to obtain a satisfactory video output.
3
Loosen the F.B. (flange back) lock ring.
4
Use manual or servo zoom to set the lens to telephoto.
5
Point the camera at the flange focal length adjustment chart
and rotate the focus ring to focus the image.
6
Set the zoom ring to wide angle.
7
Rotate the F.B. adjustment ring to focus on the chart.
Take care not to move the focus ring.
8
Repeat steps 4 to 7 until the chart stays in focus all the way
from wide angle to telephoto.
9
Tighten the F.B. lock screw.
Preparing the Audio Input
Connecting a microphone to the AUDIO 1 IN
connector
Attach the microphone supplied with the HXC-FB80K to the
microphone holder on the viewfinder.
1
1
Loosen the screw and
2
open the microphone holder
clamp.
2
Place the microphone in the microphone holder.
1
Place the microphone in the holder so that “UP” is at the
top.
2
Close the microphone holder.
3
Tighten the screw.
Notes
Approx. 3 m (10 ft)
Microphone holder clamp
Содержание HXC-FB80
Страница 71: ...Sony Corporation ...