31
5-5. USING THE CONTINUOUSLY RECORDED DISC
* This disc is used in focus bias adjustment and error rate check.
The following describes how to create a continuous recording
disc.
1. Insert a disc (blank disc) commercially available.
2. Rotate the MD JOG knob and display “CREC 1MODE” (C35).
3. Press the ENTER/YES button again to display “CREC1 MID”.
Display “CREC (0300)” and start to recording.
4. Complete recording within 5 minutes.
5. Press the MENU/NO button and stop recording .
6. Press the
A
EJECT button and remove the disc.
The above has been how to create a continuous recorded data for
the focus bias adjustment and error rate check.
Note :
• Be careful not to apply vibration during continuous recording.
5-6. CHECKS PRIOR TO REPAIRS
These checks are performed before replacing parts according to
“approximate specifications” to determine the faulty locations. For
details, refer to “Checks Prior to Parts Replacement and Adjust-
ments” (See page 9).
5-6-1. Temperature Compensation Offset Check
When performing adjustments, set the internal temperature and room
temperature to 22 to 28ºC.
Checks cannot be performed properly if performed after some time
from power ON due to the rise in the temperature of the IC and
diode, etc. So, perform the checks again after waiting some time.
Checking Procedure:
1. Rotate the MD JOG knob to display “TEMP CHECK” (C12).
2. Press the ENTER/YES button.
3. “T=@@(##) [OK]” should be displayed. If “T=@@ (##) [NG]”
is displayed, it means that the results are bad.
(@@ indicates the current value set, and ## indicates the value
written in the non-volatile memory.)
5-6-2. Laser Power Check
Before checking, check the Iop value of the optical pick-up.
(Refer to 5-8. Recording and Displaying the Iop Information.)
Connection :
KMS
260B
20101
H0576
Iop = 57.6 mA in this case
Iop (mA) = Digital voltmeter reading (mV)/1 (
Ω
)
Checking Procedure:
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press the
m
button
or
M
button to move the optical pick-up.)
Connect the digital volt meter to CN105 pin
1
(I+3V) and
CN105 pin
2
(IOP).
2. Then, rotate the MD JOG knob and display “LDPWR CHECK”
(C13).
3. Press the ENTER/YES button once and display “LD 0.9 mW $
”. Check that the reading of the laser power meter become
0.84 to 0.92 mW.
4. Press the ENTER/YES button once more and display “ LD 7.0
mW $
”. Check that the reading the laser power meter and
digital volt meter satisfy the specified value.
Specified Value :
Laser power meter reading : 7.0 ± 0.2 mW
Digital voltmeter reading : optical pick-up displayed value ± 10%
(Optical pick-up label)
5. Press the MENU/NO button and display “LDPWR CHECK”
(C13) and stop the laser emission.
(The MENU/NO button is effective at all times to stop the laser
emission.)
(For details of the method for checking
this value, refer to “5-8. Recording and
Displaying the Iop Information”.)
Note 1:
After step 4, each time the ENTER/YES button is pressed,
the display will be switched between “LD 0.7 mW $
”,
“LD 6.2 mW $
”, and “LD Wp $
”. Nothing needs to
be performed here.
Laser power
meter
Optical pick-up
objective lens
Digital volt meter
BD (MD) board
CN105 pin
1
(I+3V)
CN105 pin
2
(IOP)
R
5-6-3. Iop Compare
The current Iop value at laser power 7 mw output and reference Iop
value (set at shipment) written in the nonvolatile memory are
compared, and the rate of increase/decrease will be displayed in
percentage.
Note:
Perform this function with the optical pick-up set at room
temperature.
Procedure
1. Rotate the MD JOG knob to display “Iop Compare” (C27).
2. Press the ENTER/YES button and start measurements.
3. When measurements complete, the display changes to
“±xx%yy”.
xx is the percentage of increase/decrease, and OK or NG is
displayed at yy to indicate whether the percentage of increase/
decrease is within the allowable range.
4. Press the MENU/NO button to end.
Содержание HMC-NX5MD
Страница 44: ...44 44 HMC NX5MD 6 3 SCHEMATIC DIAGRAM CD SECTION Page 50 PIN FUNCTION ...
Страница 47: ...47 47 HMC NX5MD 6 6 SCHEMATIC DIAGRAM MD SECTION 1 2 48 48 48 PIN FUNCTION ...
Страница 48: ...48 48 HMC NX5MD 6 7 SCHEMATIC DIAGRAM MD SECTION 2 2 47 47 47 52 52 PIN FUNCTION ...
Страница 49: ...49 49 HMC NX5MD 6 8 SCHEMATIC DIAGRAM MAIN SECTION 1 2 Page 52 Page 50 Page 50 ...
Страница 52: ...52 52 HMC NX5MD 6 11 SCHEMATIC DIAGRAM DIGITAL SECTION Page 48 Page 48 Page 49 PIN FUNCTION ...
Страница 54: ...54 54 HMC NX5MD 6 13 SCHEMATIC DIAGRAM PANEL SECTION Page 50 ...