26 (E)
HKSP-R80
9. Backup of Setup Data
The table data that are set from the personal computer (to be abbreviated as PC hereafter) are stored in the
RAM on the CPU-355 board. Backing up the stored data is recommended in the case of emergency such
as data are damaged or lost.
Backing up the stored data is performed using the software BZR-20 supplied with the HKSP-R80.
9-1. Connection
Connect the equipment as shown below for uploading and downloading the stored data.
Method of connecting each BZR-20 that is shown in the illustration, and the stored data that can be
uploaded and/or downloaded are described below.
BZR-20
Connection
Connection method
Setup data that can be
uploaded/downloaded
BZR-20-
1
REMOTE3 connector
RS-232C crossover cable
The various setup data of the primary
of the HKSP-R80 and a PC
(9-pin to 9-pin)
station (HKSP-R80), the Routing
Switchers 1 to 2, the Remote Panels 1
to 4, and the BZR-IF810-
1
to
2
BZR-20-
2
BZR-IF810-
1
and a PC
RS-232C crossover cable
The various setup data of the Remote
(9-pin to 9-pin)
Panels 5 to 8, and the BZR-IF810-
1
BZR-20-
3
BZR-IF810-
2
and a PC
RS-232C crossover cable
The various setup data of the Remote
(9-pin to 9-pin)
Panels 9 to 12, and the BZR-IF810-
2
BZR-20-
4
DATA connector of the
Ethernet
The various setup data of the primary
primary station (HKSP-R80)
station (HKSP-R80), the Routing
and the BZR-IF810-
1
to
2
Switchers 1 to 2, the Remote Panels 1
to 4, and a PC and the BZR-IF810-
1
to
2
The various setup data of the Remote
Panels 5 to 8 and 9 to 12.
PFV-SP series
HKSP-R80
(Primary station)
Remote Panel
1-4
Remote Panel
5-8
Remote Panel
9-12
Ethernet hub
Routing Switcher 1-2