7 (E)
HKSP-R80
BIT2 : Cross-level Tie Line function valid/invalid
selector switch
Set this switch when you want to enable the cross-level tie
line function when the tie line system is constructed using
the HKSP-R80. Even if the setting is changed while the
power is on, the operation mode is not updated.
In order to change the operation mode, change the setting.
Then either turn off the power and back on, or press the
reset switch (S1201) on the CPU-355 board.
ON :
Cross-level tie line function is made valid.
OFF : Cross-level tie line function is made invalid.
BIT3 : Tie Line full display function valid/invalid
selector switch
Set this switch when you want to enable the cross-level tie line
full display function when the tie line system is constructed
using the HKSP-R80. Even if the setting is changed while
the power is on, the operation mode is not updated.
In order to change the operation mode, change the setting.
Then either turn off the power and back on, or press the
reset switch (S1201) on the CPU-355 board.
ON :
Cross-level tie line full display function is made
valid.
OFF : Cross-level tie line full display function is made
invalid.
BIT4 : Unit ID/IP setting method selector switch
Used to select the method of setting the IP address in the
data link that is connected to the DATA connector.
Even if the setting is changed while the power is on, the
operation mode is not updated. In order to change the
operation mode, change the setting. Then either turn off the
power and back on, or press the reset switch (S1201) on
the CPU-355 board.
ON :
A value that is set from a personal computer
connected to REMOTE3 becomes valid.
OFF : The IP address is “10.129
*
1
.6. [value of S801]”.
*
1: Can be changed between 129 and 191. For details,
refer to Section 4.
n
For the details of the IP address setting, refer to Section
4.
BIT5: TBL-PROT valid/invalid selector switch
Used to select whether the S-BUS table data stored in the
HKSP-R80 is protected or not, when the HKSP-R80 is set
as the primary station.
Even when a setting is changed while the power is on, the
setting is reflected on the operation of the board.
ON :
Write-protects the S-BUS table data.
OFF : Enables to write in the S-BUS table data.
BIT6: Not used
BIT7: REF A/B switch
Used to select which connector to be used as the reference
signal between REF IN A connector of the PFV-SP series
and REF IN B connector.
Even when a setting is changed while the power is on, the
setting is reflected on the operation of the board.
ON :
REF IN B connector
OFF : REF IN A connector
BIT 8: USER-DEF switch
Used to select which setting to be enabled when the
HKSP-R80 is restarted.
ON: Setting data written in the flash memory as user
default
OFF: Setting data just before restarting
n
For the procedure to write the user default value in the
flash memory, refer to the menu item “W: SAVE
CURRENT TABLE” of the secondary station (system
setup manual supplied with the HKSP-R80).
S803 (A-2)
8-pin DIP switch
Factory setting (
\
indicates the switch lever position.)
1
2
3
4
5
6
7
8
O
N