24 (E)
HKSP-R80
3.
Connect this unit with the PC.
When connecting using Ethernet:
Connect the hub for LAN with the DATA connector
using a specified cable.
When connecting using RS-232C:
Connect the PC with REMOTE3 connector using the
RS-232C cable.
Installation
1.
Turn on the power of the PC.
2.
Copy all of the program data to the PC.
3.
When this unit is used in the redundant configuration,
remove the backup CPU.
4.
Turn on the power of the PFV-SP series.
5.
Start the terminal software of the PC.
6.
Set the communication conditions of the PC.
When DATA connector is used for connection:
Set the TCP/IP for the terminal software the same as
the IP address of this unit and set the port number to
1001.
n
When connecting the PC with this unit using Ethernet,
set the high-order 1st byte to 3rd byte of the IP address
of the PC to the address same as the IP address of this
unit.
When REMOTE3 connector is used for
connection:
Baud rate
38400 bps
Data bit
8 bits
Parity
None
Stop bit
1 bit
Flow control
None
7.
Send the program data to this unit from the terminal
software.
n
Check that the codes in hexadecimal are displayed in
sequence on the status indicator of the indicator panel
of the CPU-355 board during data transmission.
8.
After completion of transmission, the data is written in
the flash memory and the CPU-355 board is automati-
cally reset.
n
If the hardware reset is activated or the power is
shutdown while data is being written to flash memory,
the program downloading is ended in failure. If the
CPU-355 board fails to start up for this reason, contact
your local Sony Sales Office/Service Center.
9.
Terminate the terminal software.
10. When connecting with the DATA connector, initialize
the information on the PC network.
n
When connecting with REMOTE3 connector, initial-
ization is not required.
Initialization procedure
(1) Display the MS-DOS prompt or command prompt
screen.
(2) Enter the following command from the command
line.
“arp
\
-d
\
XXX.XXX.X.XXX”
(Enter the IP address set to this unit to the
XXX.XXX.X.XXX portion. “
\
” indicates a
space.)
(3) Press the Enter key.
11. Repeat the steps from 5 to 9 and send all of the
program data to this unit.
Proceed to step 12 and the subsequent steps when this
system is used in the redundant configuration.
12. Turn off the power of the PFV-SP series.
13. Remove the main CPU and install the backup CPU in
the main slot.
14. Turn on the power of the PFV-SP series.
15. Repeat steps 5 to 11 and install the BZR-IF810 in the
backup CPU.
16. Turn off the power of the PFV-SP series.
17. Remove the backup CPU from the main slot and
install it in the backup slot.
18. Install the main CPU in the main slot.
Confirmation after Installation
The following procedure assumes that this unit is connect-
ed to a PC using the RS-232C.
1.
Set the switch S803-3 on the CPU-355 board to the
ON position.
2.
Connect a PC to the REMOTE3 connector using the
RS-232C cable.
3.
Make sure that the communication conditions of the
PC as follows:
38.4 kbps, 8 bits, no parity, no check