6 (E)
HKSP-R80
5
Status of power supply block
Ref. No. (Address)
LED name
Function
D1201 (D-3)
2.5 V
Lights in green:
Power supply of +2.5 V is
normal
D1204 (D-3)
12 V
Lights in green:
Power supply of +12 V is
normal.
D1206 (C-3)
5 V-1
Lights in green:
Power supply of +3.3 V
and +5 V are normal.
D1209 (C-3)
3.3 V
Lights in green:
Power supply of +3.3 V is
normal.
D1210 (D-3)
5 V
Lights in green:
Power supply of +5 V is
normal.
Others
Ref. No. (Address)
LED name
Function
D901 (E-3)
–
Factory use only
D902 (E-3)
–
Factory use only
D903 (E-3)
–
Factory use only
D904 (E-3)
–
Factory use only
D1001 (E-3)
–
Factory use only
D1211 (B-2)
–
Factory use only
D1212 (B-2)
–
Factory use only
Switch
n
If the HKSP-R80 and HKSP-R81 are installed, the two
CPU-355 boards must have the exactly same setting.
S101 (A-3): MON
This switch is used for test. (Factory use only)
S1201 (A-3): RESET
This switch resets the operation of the CPU-355 board.
S801 (A-3): Station ID/ Unit ID setting switch
8-pin DIP switch
Factory setting (
\
indicates the switch lever position.)
Sets the station ID of the HKSP-R80 when the HKSP-R80
is connected to the S-BUS data link as follows.
When the HKSP-R80 is used as the primary station, the
station ID is set to “1” regardless of setting of this switch.
When the HKSP-R80 is used as the secondary station, set
the station ID to any number other than “0”, “1” and
“255”. Be careful not to duplicate the same number of the
other equipment in the secondary station when setting the
station ID.
Sets the unit ID that is the 4th byte of the IP address using
the DIP switch (S802-4 is set to OFF) when the HKSP-
R80 is connected to DATA LAN (Ethernet). For details,
refer to Section 4.
Even if the setting is changed while the power is on, the
station/unit ID is not updated.
In order to change the station/unit ID, change the setting.
Then either turn off the main power and back on, or press
the reset switch (S1201) on the CPU-355 board.
Setup example
S802 (A-2)
8-pin DIP switch
Factory setting (
\
indicates the switch lever position.)
BIT1 : Virtual matrix function valid/invalid
selector switch
Set this switch when you want to use the virtual matrix
function. Even if the setting is changed while the power is
on, the operation mode is not updated.
In order to change the operation mode, change the setting.
Then either turn off the power and back on, or press the
reset switch (S1201) on the CPU-355 board.
ON :
Virtual matrix functions.
OFF : Virtual matrix does not function.
[1]
[2]
[4]
[8] [16] [32] [64] [128]
1
1
2
3
4
5
6
7
8
0
O
N
When the setting value is 8
<Setting value>
8 :
30 :
254 :
0 0 0 1 0 0 0 0
0 1 1 1 1 0 0 0
0 1 1 1 1 1 1 1
1 ; ON
0 ; OFF
(16
+
8
+
4
+
2)
(128
+
64
+
32
+
16
+
8
+
4
+
2)
1
2
3
4
5
6
7
8
O
N
1
2
3
4
5
6
7
8
O
N