9-4 Items in the Extended Setup Menu
Ch
apt
er 9 Set
up Men
u
s
211
REMOTE1 PORT
Select how to use the REMOTE 1-IN(9P)/REMOTE 1-OUT(9P) connectors on the
connector panel.
I&O:
Both the IN and OUT connectors are effective whether in local or remote
mode.
IN:
Only the IN connector is effective whether in local or remote mode.
OUT:
Only the OUT connector is effective whether in local or remote mode.
PANEL:
Enable to select I&O, IN, or OUT using the function menu.
Note
If you select “PANEL”, first set the user-defined function button RMT1 in any
function menu page.
For details on how to set the user-defined function buttons in function menu page,
refer to the Maintenance Manual Volume 1.
212
VIDEO REMOTE
CONTROL SELECT
Make settings for control from such as HKDV-900/503 via the VIDEO CONTROL
(9P) connector.
Sub-item
1
IMAGE
ENHANCER
(HDW-D1800 only)
Select whether to control the upconverter or downconverter when controlling the
image enhancer.
down:
Control the downconverter.
up:
Control the upconverter.
u&d:
Control both the upconverter and downconverter.
2
D2 SETUP
Select the menu item to be controlled by the SETUP dial with the D2 button on the
HKDV-900/503 pressed.
setup:
Sub-item (OUTPUT LEVEL) of menu item 713 (VIDEO SETUP
REFERENCE LEVEL)
Black:
Menu item 718 (SETUP(BLACK) LEVEL)
For details, see the description of menu item 718 (see page 95).
Notes
• After changing this setting, power off this unit or HKDV-900/503 and power it on
again.
• This setting is valid only in 59.94i or 29.97PsF mode.
Menu items in the range 300 to 399, relating to editing operations
Item number
Item name
Settings
301
VAR SPEED RANGE FOR
SYNCHRONIZATION
Select the playback speed range in variable speed playback mode from a remote
controller connected to the REMOTE-1 IN(9P) connector or REMOTE-1 OUT(9P)
connector.
–1 ~ +2:
–1 to +2 times normal speed for HDCAM tape. –1 to +3 times normal
speed for Digital Betacam and MPEG IMX tapes.
~ 2.45:
–1.5 to +2.45 times normal speed for HDCAM tape.
–1.5 to +3.45 times normal speed for Digital Betacam and MPEG IMX tapes.
302
CAPSTAN RE-LOCKING
DIRECTION
In 59.94i, 29.97PsF mode
Select whether the capstan servo should lock by accelerating or decelerating
when F1 (CAPSTAN) in function menu page P04: MISC-1 is set to “4F”.
DECEL:
Lock by decelerating.
ACCEL:
Lock by accelerating.
In 50i, 25PsF mode
Select whether the capstan servo should lock by accelerating or decelerating
when F1 (CAPSTAN) in function menu page P04: MISC-1 is set to “4F” or “8F”.
DECEL:
Lock by decelerating.
ACCEL:
Lock by accelerating.
Menu items in the range 200 to 299, relating to the remote control interface (Continued)
Item number
Item name
Settings