3-6
HDPS-M10
How to change the drive letter:
1)
Select “Setup” of the start menu of Windows on the PC.
2)
Select “Control panel” and open it.
3)
Open “Administrative Tools”.
4)
Open “Computer Management”.
5)
Double click “Disk management”.
6)
Left-click the drive which you want to change the drive letter,
then select “Change drive letter or paths”
7)
Click “Change”.
8)
Choose a drive letter, which you want to change, and click
“OK”.
How to fit the “FC1” application program to your computer
1)
Right-click the “Storager.seq” file of the “FC1” folder, then
select “Open”.
2)
Choose the “Notepad” from the list of apprications, then click
“OK”.
3)
The notepad application starts, and the edit screen of the
“Storager.seq” file is displayed.
4)
Change the drive letters as follows.
G:
t
Drive letter of HDPS-M10’s hard disk drive that
displayed on your computer system.
E:
t
Drive letter of HDPS-M10’s MemoryStick drive that
displayed on your computer system.
F:
t
Drive letter of HDPS-M10’s CompactFlash/Microdrive
drive that displayed on your computer system.
5)
Change the holder name of the hard disk drive into the actual
holder name of that of HDPS-M10.
PARAMETER1
g:\STORE.IPS\20050608.001\
t
\20050505.001\
PARAMETER1
g:\STORE.IPS\20050608.002\
t
\20050505.002\
PARAMETER1
g:\STORE.IPS\20050608.003\
t
\20050505.003\
6)
Save the “Storager.seq” file.
7)
Right-click the “Storager.cfg” file of the “FC1” folder, then
select “Open”.
8)
Choose the “Notepad” from the list of apprications, then click
“OK”.
9)
The notepad application starts, and the edit screen of the
“Storager.cfg” file is displayed.
10) Change the drive letters as follows.
G:
t
Drive letter of HDPS-M10’s hard disk drive that
displayed on your computer system.
E:
t
Drive letter of HDPS-M10’s MemoryStick drive that
displayed on your computer system.
F:
t
Drive letter of HDPS-M10’s CompactFlash/Microdrive
drive that displayed on your computer system.
11) Save the “Storager.cfg” file.
Storager.seq
#################################################
# #
# #
# Sequence parameter file for STORAGER
#
# #
# #
#################################################
#################################################
FUNCTION CHECK_FIRM
EXECUTION UNDO
COMMENT1 CHECK FIRMWARE 1.06
PARAMETER1
1.06
PARAMETER2
3
#################################################
FUNCTION DISC_INSERT
EXECUTION DO
COMMENT1 INSERT_MEDIA_MSPRO
PARAMETER1
MSPro
#################################################
# FILE_COMPARE
#
#
#
#PARAMETER1 Source File
#
#PARAMETER2 Target File
#
#################################################
FUNCTION FILE_COMPARE
EXECUTION DO
COMMENT1 COMPARE_FILE_MSPRO
COMMENT2
e:\trf_file.001
PARAMETER1 g:\STORE.IPS\20050505.001\trf_file.001
PARAMETER2 e:\trf_file.001
#################################################
FUNCTION DISC_EJECT
EXECUTION DO
COMMENT1 EJECT_MEDIA_MSPRO
PARAMETER1
MSPro
#################################################
#################################################
FUNCTION DISC_INSERT
EXECUTION DO
COMMENT1 INSERT_MEDIA_CF
PARAMETER1
Compact Flash
#################################################
•
•
•
COMMENT2
f:\trf_file.002
PARAMETER1 g:\STORE.IPS\20050505.002\trf_file.002
PARAMETER2 f:\trf_file.002
•
•
•
COMMENT2
f:\trf_file.003
PARAMETER1 g:\STORE.IPS\20050505.003\trf_file.003
PARAMETER2 f:\trf_file.003
•
•
•
Fig. 3-1-8.