35
Menu List
The following conventions are used in the menu list table.
Settings column values (e.g. ON, OFF, 0):
Default settings are underlined
Execute using ENTER:
Press the CONTROL knob or move the CANCEL/ENTER lever to the ENTER position to execute.
SYSTEM OPERATION menu
Note
SYSTEM OPERATION
Page name
Page No.
Item
Set value
Indication
<CAMERA I/F>
S01
OUTPUT
CAMERA,
BAR
, TEST1, TEST2
Selects the output signal.
TEST1 and TEST2 are not selectable if there is no
communication with the camera.
LASER DIODE
ON,
OFF
Turns the optical signal output from the CCU to the
camera ON/OFF.
(Displayed only when connected using optical fiber
composite cable.)
START UP VIDEO
SIGNAL
BARS
, GRAY
Selects the signal to output until the unit connects
with the camera after power-on.
<GENLOCK>
S02
REFERENCE
(NOT DETECTED), (1080/59.94I),
(1080/23.98PsF), (720/59.94P),
(1080/50I), (1080/24PsF), (720/
50P), (UNKNOWN)
Signal input of the Reference connector (Display
only)
LOCK STATUS
(LOCKED), (NOT LOCKED)
Lock status of the external reference signal (Display
only).
GENLOCK
HD,
SD
, NETWORK
Selects the lock mode of the external reference
signal. (NETWORK is displayed when HKCU-4001 is
installed.)
10F BB
OFF
, ON
Sets whether to use the 10Field ID added to the
external reference signal
This can be selected when GENLOCK is SD and
<MULTI FORMAT> page
t
SYSTEM is 1.001(525).
H-PHASE STEP
When HD is selected in
GENLOCK:
–3.01 to +3.45 µsec
0.00
When SD is selected in
GENLOCK:
–8.29 to +9.48 µsec
0.00
Adjusts the horizontal lock phase in relation to the
reference signal (steps)
H-PHASE COARSE
–99 to 99
0
Adjusts the horizontal lock phase in relation to the
reference signal (fine adjustment)
V-PHASE
0
to 7
Adjusts the vertical lock phase in relation to the
reference signal (lines)
SYNC OUT SELECT
SD SYNC
, HD SYNC
Sets the output signal of the CHARACTER/SYNC
OUT connector
This is enabled only when MAINTENANCE Menu
t
<I/F SETTINGS> page
t
CHARACTER/SYNC is